Chemdose Troubleshooting
P
ROBLEM
C
AUSE
R
EMEDY
Switch or timer settings
incorrect
In line strainer clogged
Remove strainer bowl
and clean filter
Review manual operat-
ing procedures
Pump will not prime
Leak in suction side of
pump
Inlet tubing restricted or
kinked
Incorrect volume
Check battery charge
level
Recharge battery
Debris in pump valves
Disassemble pump and
clean out debris
Check all connections
and repair any leaks
Damaged pump valves
Disassemble pump and
replace valves
Clogged nozzle
Disassemble, clean and
re-install
Charger "Fault" signal
Confirm the correct
timer setting
Improper voltage
Damaged Battery
Charger
Check chart on unit
and step time
Get a replacement
charger from Dramm
Blown fuse
Check for cause and
repair, then replace fuse
Unit will not run
Battery not charged
Fully charge battery
Use voltage adapter
Chemdose Manual
15