background image

EIA/NCTA

Numeric

Equivalent

86
87
88
89
90
91
92
93
94

100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135

Frequency

in MHz

597
603
609
615
621
627
633
639
645
651
657
663
669
675
681
687
693
699
705
711
717
723
729
735
741
747
753
759
765
771
777
783
789
795
801
807
813
819
825
831
837
843
849
855
861

CATV CHANNEL  FREQUENCIES         11

TABLE 1: CATV

Channel

Number

CABLE  TV  CHANNELS

Center of

Channel

EIA/NCTA

Numeric

Equivalent

2
3
4
5
6

95
96
97
98
99
14
15
16
17
18
19
20
21
22

7
8
9

10
11
12
13
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Frequency

in MHz

57
63
69
79
85
93
99

105
111
117
123
129
135
141
147
153
159
165
171
177
183
189
195
201
207
213
219
225
231
237
243
249
255
261
267
273
279
285
291
297
303
309
315
321

Channel

Number

CABLE TV CHANNELS

Center of

Channel

Channel

Number

CABLE  TV  CHANNELS

Center of

Channel

EIA/NCTA

Numeric

Equivalent

41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85

Frequency

in MHz

327
333
339
345
351
357
363
369
375
381
387
393
399
405
411
417
423
429
435
441
447
453
459
465
471
477
483
489
495
501
507
513
519
525
531
537
543
549
555
561
567
573
579
585
591

Summary of Contents for SCT4860

Page 1: ...Instruction Manual TM is a registered trademark of the R L Drake Company Copyright 2008 R L Drake Company P N 3852388B 1 2008 SCT4860 Transcoder System...

Page 2: ...be moved with care Quick stops excessive force and uneven surfaces may cause the product and cart combination to overturn The lightning flash with arrow head symbol within an equilateral triangle is i...

Page 3: ...grounded so as to provide some protection against voltage surges and built up static charges Article 810 of the National Electrical Code ANSI NFPA 70 provides information with regard to proper ground...

Page 4: ...C RS232 CONTROL Data Link RS232 Input RS232 Output GENERAL Operating Temperature Range Size Weight Power Requirement 950 MHz to 2150 MHz 500 kHz 5 0 MHz minimum 25 dBm to 70 dBm 75 Ohms return loss of...

Page 5: ...ends though the front panel hole the LED is properly aligned behind its front panel hole and the hook shaped projection on the bottom of the module engages the rear of the mounting tray Secure the mod...

Page 6: ...ever power is applied REARPANELCONNECTIONS R1 RS232 OUT This RS232 serial connector can connect to the RS232 IN connector on another rack containing a PS150 PS151 or PS100 power supply included transc...

Page 7: ...shown on the bottom line For set up purposes it is best to progress clockwise in the chart below use the right arrow button starting from the RS232 adjustment on the PS151 and the MODE menu for each o...

Page 8: ...R button in addition to moving to an adjacent transcoder Note that many of the parameters will not be changed until the ENTER button is pressed These include MODE related settings LNB type IF FREQ BD...

Page 9: ...multiple power supply voltages that are all obtained from the Drake model PS151 power supply module The PS151 mounts in the RMT150 rack tray along with one to ten SCT4860 or other similar Drake models...

Page 10: ...irmware to the SCT4860 if needed for use with future options For remote control operation PS150 SCT1860 systems and or PS100 SCT860 systems can be daisy chained with PS151 SCT2860s SCT3860s and SCT486...

Page 11: ...4 15 16 17 18 19 20 21 22 7 8 9 10 11 12 13 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Frequency inMHz 57 63 69 79 85 93 99 105 111 117 123 129 135 141 147 153 159 165 171 177 183 189 195 2...

Page 12: ...527 533 539 545 551 557 563 569 575 581 587 593 599 605 611 617 623 629 635 641 647 653 659 665 671 677 683 689 695 701 707 713 719 725 731 737 743 749 755 761 767 773 779 785 791 797 803 14 15 16 17...

Page 13: ...king days after it arrives at R L DRAKE if we have all the facts If we must call you it may take longer R L DRAKE is not responsible for damage caused by lightning nonprofes sional alterations acts of...

Page 14: ...ce repair anduseareimportanttoobtainproperperformancefromthisproduct Thereforecarefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE COMPANY determines is due...

Page 15: ...R L Drake Company 230 Industrial Drive Franklin Ohio 45005 U S A Customer Service and Parts Telephone 1 937 746 6990 Telefax 1 937 806 1576 World Wide Web Site http www rldrake com...

Reviews: