HOW THE MEMbRANE WORkS
Cutting pliers
Measuring Tape
phillips Screwdriver
Hole Saw
2.25” (57 mm)
Drill
0.5” (12.5 mm) bit
Mitre-Box and Saw
pVC pipe Cutter
2” (50 mm)
Regular Screwdriver
Socket Head Screwdriver
(for the clamps)
(supplied with the unit)
tHe tooLs You wiLL NeeD
or
INSTALLING THE UNIT
-
fIRST THINGS fIRST -
As illustrated on pages 6 and 7 of this manual, the Automatik system evacuates its wastewater automatically
after approximately 10 minutes. The membrane allows you to adjust the time lapse during which the unit will
deactivate before restarting its cycle; the default time lapse is 20 seconds.
Setting the timing can only be done when the unit is in use (not while it is evacuating the wastewater).
Evacuation Time
minimum : 5 seconds
maximum : 35 seconds
wHY CHANGe tHis pArAmeter?
• With a lower tank model, the unit can reactivate as soon as there is no wastewater left to flow through
the rubber hand (in other words when all the wastewater is in the lower tank).
• If the unit’s drain is located very close to the pipe leading to the sewer and that there is less restriction
to the amount of wastewater that can be evacuated, the evacuation time could only take 15 seconds.
• On the other hand, if the diameter of the pipe leading to the sewer is smaller and restrains the amount
of water that can be evacuated, increasing the evacuation time to over 20 seconds could be necessary.
settiNG tHe eVACuAtioN timeFrAme
Press on one button only to set the time to 5, 10 or 20 seconds. Or consecutively press on two or three but-
tons to set the respective timing.
example :
25 seconds of evacuation time