background image

 (; 

 4$ 

 4% 

 4& 

*HQHUDO7ROHUDQFH

 46 

 4) 

2FFXUV

0RGLILFDWLRQ7H[W

6HFWLRQIRU$$&DGGHG
UHYLVLRQVNLSSHGGXHWRWHFKQLFDOLVVXHV

&KHFNHG E\

$SSURYHGE\

3DJH

 

7LWOH

'RFXPHQW1XPEHU 5HYLVLRQ

&6$&RQWURO'UDZLQJ$$&[[$$&

6(  

$33529$/

S

c

hutz

v

er

me

rk IS

O 1

6

0

16 

be

ach

ten

.

Use o

f th

is

 d

o

cu

me

nt /

 co

nte

n

ts is

 fo

rbi

dde

n

with

o

u

e

x

p

ress

ed writt

en au

th

o

rity.

 All righ

ts

 r

e

se

rve

d

.

Dräg

er

Notes

1. Selected

“Ex i”

-Equipment shall have intrinsically safe outputs for 

Ex ia IIC T4 Ga
Class I, Zone 1, AEx ia IIC T4 Ga

2.

Caution

: Use connection XEXT1 either for charging (pin 4,5) outside the hazardous area or the 

RS485 port (pin 1,2,3). Using XEXT1 for both applications at the same time is not permitted.

3.

Caution

: Use connection XEXT2 either for the relay output (pin 4, 5, 6) or the RS485 port (pin 1,2,3). 

Using XEXT2 for both applications at the same time is not permitted.

4.

Warning:

Live maintainance is not permitted in Zone 0 areas.

5.

Warning:

Substitution of components may impair intrinsic safety.

6.

Cable Parameters

If cable parameters are unknown, use the following parameters:

Cable Capacitance:  C

c

= Ccable = 60 pF/ft (200 pF/m)

Cable inductance: L

c

= Lcable = 200 nH/ft  (660 nH/m)

„Ex i“ 

- Equipment:

Uo <= 8.01 V

Io <= 0.105 A
Po <= 0.21 W
Co <= 350 nF
Lo <= 250 uH

RS485-A

RS485-B

XEXT1

Ex i Equipment

Uimax

8.01 V

>=

8.01 V

Iimax

0.105 A

>=

0.105 A

Pimax

0.21 W

>=

0.21 W

Ci

250 nF

+C

c

<=

350 nF

Li

100 uH

+L

<=

250 uH

Shielding optional

„Ex i“ 

- Equipment:

Uo <= 8.01 V

Io <= 0.105 A
Po <= 0.21 W
Co <= 350 nF
Lo <= 250 uH

RS485-A

RS485-B

Shielding optional

XEXT2

Ex i Equipment

Uimax

8.01 V

>=

8.01 V

Iimax

0.105 A

>=

0.105 A

Pimax

0.21 W

>=

0.21 W

Ci

250 nF

+C

c

<=

350 nF

Li

100 uH

+L

<=

250 uH

2 (3)

2 (3)

Thomas Treptow
2020-12-08T11:07:20

Andreas Suerig
2020-12-08T11:58:01

Title

Document Number - Revision

Page

&6$&RQWURO'UDZLQJ$$&[[$$&

6(  

 

$33529$/

S

c

hutz

v

er

me

rk IS

O 1

6

0

16 

be

ach

ten

.

Use o

f th

is

 d

o

cu

me

nt /

 co

nte

n

ts is

 fo

rbi

dde

n

with

o

u

e

x

p

ress

ed writt

en au

th

o

rity.

 All righ

ts

 r

e

se

rve

d

.

Dräg

er

AAC 00xx and AAC 03**
can be connected with non-
intrinsically safe quipment 
(e.g. a PC RS485 interface) 
via Z-barriers:

Notes

1.

XEXT1 and/or XEXT2 can be used 
for connection of non-intrinsically 
safe equipment via Z-barriers. As 
an example the circuit diagram 
shows a connetion to XEXT2.

2.

Series connection of the types 

Fuchs Z757

with 

Pep-

perl+Fuchs Z966H

(BAS 01 ATEX 

7005 and IECEx S06.0012 xx) is 
permitted as shown.

3.

Barrier must be installed as instruc-
ted by the manu

facturer’s control 

drawing.

4.

Caution

: Use connection XEXT1 

either for charging (pin 4,5) outside 
the hazardous area or the RS485 
port (pin 1, 2, 3). Using XEXT1 for 
both applications at the same time 
is not permitted.

5.

Caution

: Use connection XEXT2 

either for the relay output (pin 4, 5, 
6) or the RS485 port (pin 1, 2, 3). 
Using XEXT2 for both applications 
at the same time is not permitted.

6.

Warning: 

Substitution of compo-

nents may impair intrinsic safety.

7.

Cable Parameters: 

Use Belden 

3107A, 2 x 2 AWG22. Maximum 
length = 25 m = 82 ft between 
AAC 00xx and the Z-barriers.

Connection of  „Ex i“

-Equipment in Hazardous Areas

Reviews: