Dräger UCF 6000, UCF 7000, UCF 8000, UCF 9000
23
Troubleshooting
4
Troubleshooting
Malfunction
Possible cause
Remedy
Camera cannot be
switched on.
The battery is empty. Recharge the battery.
The battery screws
are loose.
Tighten screws.
Laser pointer is weak
or diffused.
Water droplets or dirt
is on the laser
emission window.
Clean the laser
emission window.
The charging cradle
LEDs indicate an
error during the
charging process.
The contacts on the
battery and/or the
charging cradle are
dirty.
Clean contacts with a
lint-free cloth.
The battery is too cold
or too hot.
Leave the battery in
the charger and place
charger in an area
with an ambient
temperature between
10 and 35 °C (50 °F
and 95 °F). The
charger will charge
the battery once the
temperature inside
the charger is correct.
It may take
significantly more
than an hour before
the internal
temperature reaches
the permissible range
again and charging
resumes since the
temperature is
measured directly on
the Li-ion cells.
Malfunction
Possible cause
Remedy