Maintenance and care
If soiled
Front visor and outer hood:
must be replaced.
Head harness:
Remove connecting hose from silencer and draw it out of
the hood.
Clean, disinfect and dry basic equipment:
Clean with lukewarm water containing Sekusept Cleaner (Fa.Henkel-
Ecolab, D-40589 Düsseldorf, Germany) and a cloth.
Rinse thoroughly under running water.
Only use approved disinfectants, e.g. Incidur (Fa.Henkel-Ecolab, D-40589
Düsseldorf, Germany). Note manufacturer's instructions. Rinse thoroughly
under running water.
Leave to dry in a drying cabinet (R 28 305) or in air.
Maximum temperature 60
°
C. Keep away from direct sunlight.
Polluted parts:
must be disposed of.
During work
If visibility is impaired:
Grasp one corner of front visor, draw off to side and dispose of in
accordance with the applicable waste disposal regulations.
Insert a new front visor between upper and lower row of buttons and press
into place on the adhesive strips.
After work
Leave the hazard area.
Remove hood with head harness:
Stretch rubber band in collar and draw it over your head.
Disconnect demand valve from compressed air hose:
Press both coupling halves firmly together and simultaneously draw back
the outer sleeve so that the coupling disengages. Fit cap.
Open belt and put down apparatus.
Switch off the compressed air supply.
Storage
Wipe visor with an antistatic cloth. Fold up hood, keeping visor flat. Pack
all parts in the bag supplied and store in a dry, cool and dust-free room
without deformation. Keep away from direct light and heat.
Note DIN 7716 "Guidelines for storage, maintenance and cleaning of
rubber products".
The apparatus can be stored indefinitely if the above storage conditions
and the maintenance intervals are observed.
Technical data
Compressed air
supply hose
Max. length 10 m, antistatic, heat resistant
Breathable air
As per DIN EN 12 021. Do not use oxygen or
oxygen-enriched air.
Operating pressure
6 to 8 bar
Service temperature
–10
°
C to 60
°
C, see also "Description/
intended use"
Air output
Approx. 160 litres per minute at 6 bar
Approx. 200 litres per minute at 8 bar
Noise level
Approx. 70 dB (A)
Hood
Material
Coated felt, white (Saranex)
Visor
Cellulose acetate
Front visor
Polyester
Weight
Approx. 90 g
Outer hood
Material
Uncoated felt, white
Basic equipment
Weight
Approx. 500 g
Maintenance intervals
Troubleshooting
Fault
Cause
Remedy
Unpleasant
Breathable air does not
Check compressor and
taste and
conform to DIN EN 12 021
fine
compressed air filter.
smell
Replace filter cartridge if
necessary
Loud flow
Felt inlays missing
Unscrew silencer and
noise in hood
from silencer
insert felt inlays
Draught in hood
Air volume too high
Check operating pressure
Poor visibility
Front visor soiled or
Replace front visor
scratched
Visor soiled or
Replace hood and use
scratched
a front visor
Order list
A
Compressed air line breathing apparatus with the type identification
marking Suleika II / R 27 944
B
Compressed air line breathing apparatus with the type identification
marking Suleika II / R 54 620
Designation
Order No.
A
B
For operation:
Basic equipment
R 54 200
X
X
Hood
R 53 618X
X
Compressed air supply hose,
X
X
5 m
R 54 021
10 m
R 54 022
Accessories:
Outer hood
R 53 635
X
X
Front visor (set of 100)
R 53 630
X
X
"klar-pilot" gel (demisting gel for visor)
R 52 560
X
X
Distributor (for supplying two hoods)
R 27 945
X
X
For supply from a stationary breathing
air network (loop):
Fine
compressed air filter
R 27 944
X
Compressed air hose, 15 mm inside
11 80 940
X
width (cut to required length)
Hose clip
T 50 086
X
Adapter R 3/4 to
R 20 087
X
15/19 RD 32x1/8
Union nut 15/19 RD 32x1/813 35 553
X
Conical socket
13 35 561
X
Accessories:
Fine
compressed air filter cartridge
CH 106
X
For connection to a compressed
air cylinder:
Compressed air cylinder 50 litres/200 bar
B 02 860
X
Pressure reducer 300 bar
R 54 620
X
Accesories:
Connecting element
R 19 325
X
Auxiliary cylinder 4 litres/200 bar
B 10 435
X
Testing accessories
Test gauge
on application
X
X
1) Hose and screw connections must be tight.
Test at operating pressure, using soapy water. No bubbles should form.
2) e.g. by DrägerService.
3) Only if there is a smell of oil.
5
Equipment item Work required
Hood
Clean
X
X
Disinfect
X
X
Check:
X
transparency of visor, adhesive
strength of adhesive strips
Couplings
Use a test gauge to check the
snap-on nipple for wear.
X
Check that the coupling is free-
X
moving. Clean outside of coupling.
X
Complete
Clean
X
X
compressed air
Check operation and check
X
X
line breathing
for leaks
1)
apparatus
Compressed
Fill
X
air cylinder
Check filling pressure
X
Inspection by experts
X
2)
Pressure
Replace high-pressure
reducer
sealing rings
X
2)
Basic overhaul
X
2)
Compressed air
Clean outside of hose
X
supply hose
Rinse inside with air
X
Check for leaks
1)
X
X
Fine compressed Check for leaks
1)
X
X
air filter
Replace filter cartridge
X
3)
X
Before
use
After use
Every 6 months
Once per year
Every 6 years