Instruction Manual Dräger P7-TDX
10
6. Checklists / Visual inspection
A comment can be added to the results of the visual inspec-
tion and be documented.
Checklists can be configured using the professional software PC200P. Up to 4 different
checklists each with up to 20 items can be stored, edited and documented on the device.
7. Pressure measurements
7.1 Selection of pressure measurements
The following functions can be selected:
High Pressure
= pressure measurements up
to 3500 hPa (mbar)
Medium Pressure
= pressure measurements up
to 150 hPa (mbar)
Micro Pressure
= pressure measurements up to 100 Pascal
Pump (150 hPa (mbar)) = medium pressure measurement with pump function
High pressure ext. (MPa)(bar) = high pressure measurement with external sensor
up to 2.5 MPa (25 bar)
Pressure monitor
= recording of pressure fluctuations
Diff. Pressure (± 2 MPa (20 bar)) = differential pressure measurement with 2 external
pressure sensors
Differential pressure measurements with the integrated pressure sensor (150 hPa (mbar))
are conducted in the “medium pressure” function. Select the “differential pressure (± 2.0
MPa (20 bar))” function for differential pressure measurements with external high pressure
sensors.