Replacing the Batteries

Insert a new battery when using an alkaline cell as power supply and 
the battery symbol on the display indicates "empty".

Gently press the lock on the battery cover and remove the cover.

Remove the used batteries and insert new ones
 – ensure correct polarity!

Close the battery cover.

Required batteries:

2 x 1.5 V alkaline cells (Mignon, LR6, AA)
.

Dispose of batteries as special waste according to local waste dis-
posal regulations.
Information can be obtained at local environmental protection agen-
cies and town clerk offices as well as at suitable waste disposal com-
panies.
Always have spare batteries at hand to be able to immediately con-
tinue use of the device after the first set of batteries is spent.

How to Dispose of the Device

Since August 2005, regulations concerning the disposal of 
electrical and electronic devices have come into force in the 
entire European Union; these regulations are specified in 
the Directive 2002/96/EC of the European Parliament and in 

national laws relating to this device.
Special collection and recycling possibilities have been established 
for private households.

CAUTION

Danger of explosion!
Do not throw used alkaline cells into open fire, do not recharge 
them and do not try to force them open.

Summary of Contents for Alcotest 3000

Page 1: ...D Instructions for Use Dr ger Alcotest 3000 ST 14138 2008_sw eps Breath Alcohol Measuring Device...

Page 2: ...F 6 Switching ON 6 Switching OFF 6 Automatic Switch OFF 6 Making Measurement 7 Requirements 7 Requirements for the Test Subject 7 Automatic Measurement 7 Errors during Breath Sample Delivery 8 Removin...

Page 3: ...s Only use accessories mentioned in the order list Safety Symbols used in this Manual While reading this manual you will come across a number of warn ings concerning some of the risks and dangers you...

Page 4: ...om the power up display and or the label on the rear of the device What is What 1 Display 2 ON OFF button 3 Socket for the Dr ger service personnel only 4 Lamp red green 5 Mouthpiece connection Prepar...

Page 5: ...Indicates the state of charge of the batteries Full battery Battery capacity 2 3 full Battery capacity 1 3 full Low battery Buttons ON OFF button Button to switch the device on off and to continue th...

Page 6: ...N and OFF Switching ON Keep the button pressed for approx 1 second until the start screen is displayed Switching OFF Keep the button pressed The device switches off after two seconds Automatic Switch...

Page 7: ...drinks aromatic beverages e g fruit juices uses alcoholic mouth spray or consumes medical syrup or drops Rinsing out the mouth with water or non alcoholic bev erages will not help reduce the waiting p...

Page 8: ...play while the breath sample is taken After delivering a sufficient breath sample the green lamp goes out and the continuous tone falls silent WAIT Analyzing appears on the display Test Result After 5...

Page 9: ...rement During the recovery period of the sensor see Technical Data on page 13 WAIT appears on the display Removing the Mouthpiece Push the mouthpiece upwards out of the mouthpiece holder Dispose of th...

Page 10: ...umes a small amount of current even when switched off Therefore remove the batteries if the device will not be used for a longer period of time Cleaning Do not dip the device into liquids and do not a...

Page 11: ...own clerk offices as well as at suitable waste disposal com panies Always have spare batteries at hand to be able to immediately con tinue use of the device after the first set of batteries is spent H...

Page 12: ...breathing continu ously or vigourously enough Ask test subject to breathe continuously and more vigourously into the mouthpiece Error message on the display Cause Remedy The measuring range is exceede...

Page 13: ...to 5 00 g L 0 to 500 mg 100 mL 0 to 500 mg 0 00 to 5 00 mg mL This data is given using a conver sion factor of 2100 between breath and blood alcohol concentration Range of Indication The range of indi...

Page 14: ...0 05 0 005 0 03 mg L 3 g 100 mL 0 05 g L 1 00 0 100 0 50 mg L 50 g 100 mL 1 00 g l 5 of the measurement value Dimensions 140 mm x 80 mm x 35 mm W x H x D Weight approx 195 g Power Supply Batteries 2...

Page 15: ...No Dr ger Alcotest 3000 measuring device 3 mouthpieces 2 batteries wrist strap and pouch 83 20 470 Accessories Mouthpieces are hygienically tested 10 pcs 100 pcs 250 pcs 1000 pcs 68 12 287 68 10 690...

Page 16: ...aA Revalstrasse 1 D 23560 L beck Germany Phone 49 451 882 0 Telefax 49 451 882 20 80 www draeger com 90 33 083 GA 4754 510 en Dr ger Safety AG Co KGaA 2nd edition September 2008 1st edition July 2008...