1.1 

General safety statements

 

Before using this product, carefully read the Instructions for Use.

• 

Strictly follow the Instructions for Use. The user must fully understand 

and strictly observe the instructions. Use the product only for the 

purposes specified in the Intended Use section of this document.

• 

Do not dispose of the Instructions for Use. Ensure that they are 

retained and appropriately used by the product user.

• 

Only fully trained and competent users are permitted to use this 

product.

• 

Comply with all local and national rules and regulations associated 

with this product.

• 

Only trained and competent personnel are permitted to inspect, 

repair and service the product as detailed in these Instructions for 

Use (see Section 5). Further maintenance work that is not detailed 

in these Instructions for Use must only be carried out by Dräger or 

personnel qualified by Dräger. Dräger recommend a Dräger service 

contract for all maintenance activities.

• 

Use only genuine Dräger spare parts and accessories, or the proper 

functioning of the product may be impaired.

• 

Do not use a faulty or incomplete product, and do not modify the 

product.

• 

Notify Dräger in the event of any component fault or failure.

1.2 

Special and product-specific safety 

statements

• 

This product is approved according to ATEX directive 

2014

/

34

/E

U

.

It must

 

only be used under the conditions specified in the approval certificate.

• 

Ensure that all site permits, procedures and practices are followed 

when installing, using and maintaining the product.

1.3 

Definitions of alert icons

Alert icons are used in this document to provide and highlight text that 

requires a greater awareness by the user. A definition of the meaning 

of each icon is as follows:

WARNING

Indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not 

avoided, could result in physical injury or damage to the 

product or environment. It may also be used to alert against 

unsafe practices.

NOTICE

Indicates additional information on how to use the product.

!

!

i

i

For your safety

Summary of Contents for 420 94 60

Page 1: ...lame 3000 Visual Flame Detector Instructions for Use WARNING Strictly follow the Instructions for Use The user must fully understand and strictly observe the instructions Use the product only for the...

Page 2: ......

Page 3: ...xplanation of type identifying marking and symbols 8 3 Use 9 3 1 Prerequisites for installation 9 3 2 Installation 10 3 3 Commissioning and functional testing 14 4 Troubleshooting 15 5 Maintenance 16...

Page 4: ...activities Use only genuine Dr ger spare parts and accessories or the proper functioning of the product may be impaired Do not use a faulty or incomplete product and do not modify the product Notify D...

Page 5: ...e following main components Front enclosure cover including the window Detector assembly Enclosure body Terminal connections Rear enclosure cover Mounting bracket The Dr ger Flame 3000 is supplied pre...

Page 6: ...oes not have a traditional cone of vision like infrared flame detectors Its field of view is a rectangular pyramidal shape and represents a radial projection of the rectangular sensing element within...

Page 7: ...r use of the device in gas vapour air mixtures of combustible gases and vapours under atmospheric conditions The explosion protection is not valid for use in oxygen enriched atmospheres WARNING Do not...

Page 8: ...r ger Flame 3000 is insensitive to arc welding arc welding should not take place within 1 m of the flame detector 2 5 Approvals ATEX Certificate number FM07ATEX 0033 II 2 G Ex db IIC T4 IECEx Certific...

Page 9: ...the mounting position If dense smoke is expected to accumulate at the onset of the fire the Dr ger Flame 3000 should be mounted 1 2 m below the ceiling level where possible Ensure there is maintenance...

Page 10: ...should only be installed after these tests are complete Do not drop or knock the enclosure as this may damage the detector assembly Only appropriately trained service personnel may open the enclosure...

Page 11: ...he mounting location using 8 mm fastenings 2 Orientate the Dr ger Flame 3000 so that it provides the desired coverage and securely fix in place Ensure that it is orientated so that the status LED and...

Page 12: ...10 B 11 B 12 Alarm 24 Vdc 0 Vdc To fire panel To fire panel 4 20mA source 0 Vdc 24 Vdc 0 Vdc End of line resistor Alarm Alarm relay normally open Fault relay normally closed Event Output Power detecto...

Page 13: ...sure that the O ring is beneath the cover and that the set screw will not interfere with or be screwed into the threads of the flame path or the O ring Secure the rear enclosure cover in place with th...

Page 14: ...d system initialization that takes approximately five seconds 2 Test the Dr ger Flame 3000 using a flame simulator refer to the flame simulator instructions for details Dr ger recommend the Dr ger FS...

Page 15: ...pair Any attempt to dismantle remove or repair the detector assembly by persons who are not appropriately trained service personnel will invalidate the warranty of the Dr ger Flame 3000 When investiga...

Page 16: ...sks be completed every six months The actual level of maintenance required is dependant on the operating environment and the likelihood of damage or the rate of contamination from oil etc It is advisa...

Page 17: ...ive from August 2005 and apply to this device Common household appliances can be disposed of using special collecting and recycling facilities However as this device has not been registered for househ...

Page 18: ...mm 8 7 in 3 9 in Cable entries M20 M25 1 2 or 3 4 NPT single entries Terminal wire size 2 5 mm2 14 AWG Ingress protection IP66 NEMA 4X 7 2 2 Mounting bracket Support fixings M8 quantity 2 Vertical ad...

Page 19: ...m 420 94 62 Single 3 4 NPT cable entry aluminum 420 94 64 Single 1 2 NPT cable entry aluminum 420 94 76 Single M25 cable entry stainless steel 420 94 68 Single M20 cable entry stainless steel 420 94 7...

Page 20: ...raeger Safety UK Limited Ullswater Close Blyth NE24 4RG United Kingdom Tel 44 1670 352891 Fax 44 1670 544475 www draeger com 3360572 Dr ger Safety UK Limited Edition 04 March 2019 Subject to alteratio...

Reviews: