DR PILOT 5TE Safety & Operating Instructions Manual Download Page 9

CONTACT US AT 

www.DRpower.com

          9

 

Read and understand the warnings listed in “Chapter 2 General Safety Rules” before operating this Electric Log Splitter. 

 

Chapter 3: Operating the DR 5-TON ELECTRIC LOG SPLITTER 

It may be helpful to better familiarize yourself with the features of your Electric Log Splitter by reviewing Figure 1 in Chapter 2 
before beginning the steps outlined in this chapter.  This Splitter has been designed as a home use model only. It is designed for 
operating under ambient temperatures between 40° F. and 105° F. The Electric Log Splitter can be stored or transported under 
ambient temperatures between -10° F. and 130° F. 

Before Splitting Wood 

Inspect the area in which you will be working. 

 

Place the Electric Log Splitter only on a firm, level, supported surface 24-32 inches above the ground. 

 

NEVER operate the Electric Log Splitter on the ground as there is risk of injury and would not be comfortable for the operator 
while in use. 

 

The site must be free of slippery surfaces and potentially hazardous obstacles.  Also, make sure there won't be people or 
animals within a six-foot radius around the Electric Log Splitter. 

Plan your work before you start. 

 

Have the logs that you are splitting positioned where you can easily reach them.  Remember, the maximum log length is 20" 
and the maximum diameter is 10" for this Electric Log Splitter. 

 

Have a site located where the split wood can be stacked or loaded onto a truck or nearby carrier.

 

1.

 

Prior to using the Electric Log Splitter, open the Air Bleed Screw by turning 
the Thumbscrew counter-clockwise three to four times (Figure 4).  Leave the 
Air Bleed Screw open in this position while using the machine.
  We 
recommend closing the Air Bleed Screw after each use, but you can leave the 
Air Bleed Screw open when you are finished. 

NOTE:  If you are going to transport the machine you should close the Air Bleed 

Screw being careful not to over tighten

 and strip the screw. 

2.

 

Connect the Electrical Cord from the Electric Log Splitter to a standard electrical, 110-120VAC, grounded power source fused at 
15 AMPS.  If using an extension cord, it must be 12AWG and less than 25 feet long or 10AWG and less than 50 feet long with a 
rating of 15 AMPS.  Route the cord from the Electric Log Splitter to the power source in such a way that safeguards against 
damaging the cord during the wood splitting session.  Be sure to avoid wet conditions. 

Tip:  In cold weather, see “Specifications” in Chapter 2 for hydraulic fluid information and cycle the Ram to warm up the hydraulic 
fluid.  This will provide full power from your DR 5-TON ELECTRIC LOG SPLITTER. 

Air Bleed 
Screw 

Figure 4 

 

Always make certain that the machine is on a firm level surface and off 
the ground at a comfortable height (24-32 inches). 

 

It is important that the Air Bleed Screw is open when you use the Electric 
Log Splitter (Figure 4).  Open the Air Bleed Screw by turning it counter-
clockwise three to four times.  Failure to open the Air Bleed Screw before 
using could damage the Electric Log Splitter. 

 

Use care, do not over tighten and strip the Air Bleed Screw threads when 
screwing in for transport. 

Summary of Contents for PILOT 5TE

Page 1: ...structions before operating the DR 5 TON ELECTRIC LOG SPLITTER Serial No Order No DR Power Equipment Toll free phone 1 800 DR OWNER 376 9637 Website www DRpower com DR 5 TON ELECTRIC LOG SPLITTER SAFE...

Page 2: ...n your order history and is located on your packing slip For your convenience and ready reference enter the Serial Number and Order Number in the space provided on the front cover of this manual Addit...

Page 3: ...NER 376 9637 and one of our Technical Support Representatives will be happy to help you Chapter 1 General Safety Rules Labels Your DR 5 TON ELECTRIC LOG SPLITTER carries prominent labels as reminders...

Page 4: ...lic fluid can remain pressurized while the motor is off due to the return spring force on the ram Always follow these precautions Always release residual energy from pressurized hydraulic fluid and al...

Page 5: ...in melting of the insulation or even create a fire Always keep the electrical cord and or extension cord away from excessive heat oil and sharp objects Safety for Children and Pets Safety with Electr...

Page 6: ...as squarely as possible Never split more than one log at a time unless you fully extended the ram and you need a second log to complete the split of the first log Never put anything between the log gu...

Page 7: ...these procedures If you have any questions at all please feel free to contact us at www DRpower com DR 5 TON ELECTRIC LOG SPLITTER Controls and Features Splitting Wedge Log Ram Rubber Wheels Oil Pump...

Page 8: ...ifficult to split logs with regular fibers even if its diameter exceeds the 10 max indicated above Log Splitter is shipped with Hydraulic Fluid already added Assembly Tools Needed Pliers 16mm Wrench 1...

Page 9: ...Prior to using the Electric Log Splitter open the Air Bleed Screw by turning the Thumbscrew counter clockwise three to four times Figure 4 Leave the Air Bleed Screw open in this position while using...

Page 10: ...ings listed in Chapter 1 General Safety Rules before operating this DR Dual action electric log splitter If any doubt or question arises about the correct or safe method of performing anything found i...

Page 11: ...dle Figure 9 Figure 8 Figure 7 Do not place your hands on the ends of the log when loading the Log Splitter This is a very UNSAFE method and could result in injury to your hands Figure 7 Do not reach...

Page 12: ...o of the Control Lever and the Ram will return to the retracted position If the log does not split immediately do not continue the forward thrust of the ram for more than five seconds This can damage...

Page 13: ...eed to have someone support the Electric Log Splitter to prevent tipping over Clean the area around the Hydraulic Fluid Fill Drain Port Figure 12 and then using a 6mm Allen Wrench unscrew and remove t...

Page 14: ...when checking remove and check the level it should be between the two marks on the Dipstick If the fluid is too high simply pour out a little at a time into a suitable container by tilting the Electr...

Page 15: ...um diameter of 10 for the DR 5 TON ELECTRIC LOG SPLITTER The Splitting Wedge has burrs or nicks and needs sharpening There may be a hydraulic fluid leak Locate the leak using a piece of cardboard unde...

Page 16: ...39 A0000938026 Plastic Sleeve 40 A0000938024 Nut M6 41 A0000944999 Set Screw Internal Hex Head M6 X 20 42 A0000938023 Hex Nut 43 A0000938022 Bushing Short Shaft 44 A0000937683 Washer Lock 10 Ref Part...

Page 17: ...CONTACT US AT www DRpower com 17 Schematic DR 5 TON ELECTRIC LOG SPLITTER...

Page 18: ...esponsible for the performance of the required maintenance as defined by the manufacturer s owner s manuals The warranty holder is responsible for replacement of normally wearing parts This warranty d...

Page 19: ...CONTACT US AT www DRpower com 19 Notes...

Page 20: ...the DR 5 TON ELECTRIC LOG SPLITTER to remove any moisture wood chips and dirt that may have accumulated on the Log Guides and Operating Handle Apply a thin coating of oil or 2 Lithium Grease to the l...

Reviews: