background image

CONTACT US AT 

www.DRpower.com

          5

 

Never overlook the hazards of electricity.  Always follow these precautions: 

 

Never open the switch box or motor cover.  Never attempt any electrical repairs yourself.  If in doubt, consult a qualified 
electrician, visit our website at www.DRpower.com or contact DR Power Equipment for toll-free support at: 1-800-dr-owner 
(376-9637) for help or information. 

 

Never use an extension cord that is not rated for outdoor use. 

 

Never operate the Electric Log Splitter if there is an electrical hazard present. 

 

Never operate the Electric Log Splitter in wet conditions. 

 

Never operate the Electric Log Splitter with a damaged electrical cord or damaged extension cord. 

 

Never pull on the electrical cord to move the machine. 

 

Always grasp the electrical cord plug when unplugging the cord from the outlet; never pull the plug out by the cord.  Make 
sure your fingers do not touch the metal prongs when plugging or unplugging. 

 

Never operate the Electric Log Splitter unless the electrical cord is plugged into a properly grounded outlet, which supplies 
110-120v power, and is protected by a 15-amp circuit breaker. 

 

Never tamper with safety devices.  Check their proper operation regularly. 

 

If you will use an extension cord, keep the connection between the electrical cord and the extension cord well away from any 
water. 

 

Never use an extension cord longer than 25 feet and smaller than 12 awg in diameter, or longer than 50 feet and smaller than 
10 awg in diameter; the cord will produce a voltage drop that will prevent the motor from supplying full power and may cause 
damage to the motor. Use of a smaller diameter (larger awg number) extension cord could result in melting of the insulation 
or even create a fire. 

 

Always keep the electrical cord and/or extension cord away from excessive heat, oil, and sharp objects. 

Safety for Children and Pets 

Safety with Electric - Powered Machines 

General Safety 

Tragic accidents can occur if the operator is not alert to the presence of children and pets.  Children are often attracted to the 
machine and the splitting activity.  

Never 

assume that children will remain where you last saw them.  Always follow these 

precautions:

 

 

Keep children and pets at least 50 feet from the working area and ensure they are under the watchful care of a responsible 
adult. 

 

Be alert and turn the machine off if children or pets enter the work area. 

 

Never allow children to operate the Electric Log Splitter.

 

Operating this Electric Log Splitter safely is necessary to prevent or minimize the risk of death or serious injury.  Unsafe operation 
can create a number of hazards for you.  Always take the following precautions when operating this Electric Log Splitter: 

 

Your Electric Log Splitter is a powerful tool, not a plaything.  Exercise extreme caution at all times.  The machine is designed 
to Split Logs.  Do not use it for any other purpose. 

 

Know how to stop the Electric Log Splitter quickly; see “stopping the Electric Log Splitter” in Chapter 3. 

 

Never operate your unit on a slippery, wet, muddy, or icy surface.  Exercise caution to avoid slipping or falling. 

 

Check the Electric Log Splitter before turning it on.  Never use the machine without ensuring that all guards and shields are in 
place.  Replace damaged, missing or failed parts before using the Splitter. 

 

Never, under any conditions, remove, bend, cut, fit, weld, or otherwise alter standard parts on the Electric Log Splitter.  This 
includes all shields and guards.  Modifications to your machine could cause personal injuries and property damage and will 
void your warranty. 

 

Summary of Contents for PILOT 5TE

Page 1: ...structions before operating the DR 5 TON ELECTRIC LOG SPLITTER Serial No Order No DR Power Equipment Toll free phone 1 800 DR OWNER 376 9637 Website www DRpower com DR 5 TON ELECTRIC LOG SPLITTER SAFE...

Page 2: ...n your order history and is located on your packing slip For your convenience and ready reference enter the Serial Number and Order Number in the space provided on the front cover of this manual Addit...

Page 3: ...NER 376 9637 and one of our Technical Support Representatives will be happy to help you Chapter 1 General Safety Rules Labels Your DR 5 TON ELECTRIC LOG SPLITTER carries prominent labels as reminders...

Page 4: ...lic fluid can remain pressurized while the motor is off due to the return spring force on the ram Always follow these precautions Always release residual energy from pressurized hydraulic fluid and al...

Page 5: ...in melting of the insulation or even create a fire Always keep the electrical cord and or extension cord away from excessive heat oil and sharp objects Safety for Children and Pets Safety with Electr...

Page 6: ...as squarely as possible Never split more than one log at a time unless you fully extended the ram and you need a second log to complete the split of the first log Never put anything between the log gu...

Page 7: ...these procedures If you have any questions at all please feel free to contact us at www DRpower com DR 5 TON ELECTRIC LOG SPLITTER Controls and Features Splitting Wedge Log Ram Rubber Wheels Oil Pump...

Page 8: ...ifficult to split logs with regular fibers even if its diameter exceeds the 10 max indicated above Log Splitter is shipped with Hydraulic Fluid already added Assembly Tools Needed Pliers 16mm Wrench 1...

Page 9: ...Prior to using the Electric Log Splitter open the Air Bleed Screw by turning the Thumbscrew counter clockwise three to four times Figure 4 Leave the Air Bleed Screw open in this position while using...

Page 10: ...ings listed in Chapter 1 General Safety Rules before operating this DR Dual action electric log splitter If any doubt or question arises about the correct or safe method of performing anything found i...

Page 11: ...dle Figure 9 Figure 8 Figure 7 Do not place your hands on the ends of the log when loading the Log Splitter This is a very UNSAFE method and could result in injury to your hands Figure 7 Do not reach...

Page 12: ...o of the Control Lever and the Ram will return to the retracted position If the log does not split immediately do not continue the forward thrust of the ram for more than five seconds This can damage...

Page 13: ...eed to have someone support the Electric Log Splitter to prevent tipping over Clean the area around the Hydraulic Fluid Fill Drain Port Figure 12 and then using a 6mm Allen Wrench unscrew and remove t...

Page 14: ...when checking remove and check the level it should be between the two marks on the Dipstick If the fluid is too high simply pour out a little at a time into a suitable container by tilting the Electr...

Page 15: ...um diameter of 10 for the DR 5 TON ELECTRIC LOG SPLITTER The Splitting Wedge has burrs or nicks and needs sharpening There may be a hydraulic fluid leak Locate the leak using a piece of cardboard unde...

Page 16: ...39 A0000938026 Plastic Sleeve 40 A0000938024 Nut M6 41 A0000944999 Set Screw Internal Hex Head M6 X 20 42 A0000938023 Hex Nut 43 A0000938022 Bushing Short Shaft 44 A0000937683 Washer Lock 10 Ref Part...

Page 17: ...CONTACT US AT www DRpower com 17 Schematic DR 5 TON ELECTRIC LOG SPLITTER...

Page 18: ...esponsible for the performance of the required maintenance as defined by the manufacturer s owner s manuals The warranty holder is responsible for replacement of normally wearing parts This warranty d...

Page 19: ...CONTACT US AT www DRpower com 19 Notes...

Page 20: ...the DR 5 TON ELECTRIC LOG SPLITTER to remove any moisture wood chips and dirt that may have accumulated on the Log Guides and Operating Handle Apply a thin coating of oil or 2 Lithium Grease to the l...