background image

Dr. meter Non-Contact Infrared Thermometer

Model: IR-60

User Manual

Safety Information

Please read this user manual carefully before using the thermometer.

Do not clean the thermometer with any solvents.

Safety symbols:

Important notices against hazards

Compliant with European CE safety directive

This thermometer complies with the standards provided below:

EN61326-1

EN60825-1

Warning!

Do not point the thermometer’s laser at anyone’s eyes, or let the beam strike the eyes from

any reflective surface.

Important Notices

When introducing the thermometer to a new environment, allow the unit 30 minutes to

adjust to temperature changes before usage. Temperature measurement can only resume

when the meter’s temperature is consistent with the new environment temperature.

Keep the unit away from EMF (electro-magnetic fields) and induction heaters.

Do not point the unit’s laser directly at eyes.

Do not leave the unit on or near objects with high temperatures.

Do not use this unit in areas where explosive gas, steam, dust and smog are present to

ensure uninterrupted measurement results.

Keep the thermometer’s lens cone free from frost, oil and dirt to ensure accurate

temperature readings.

Product Illustration

Summary of Contents for IR-60

Page 1: ...mportant Notices When introducing the thermometer to a new environment allow the unit 30 minutes to adjust to temperature changes before usage Temperature measurement can only resume when the meter s...

Page 2: ...9 Trigger button 10 Battery cover 1 Primary display panel displays measured temperature 2 Functional indication displays Max HAL high alarm level LAL low alarm level E emissivity 3 Secondary display p...

Page 3: ...set value The default upper limit alarm value for this instrument is 5 and the default lower limit value is 5 2 Set the emissivity Press the trigger button to power up the device The functional indic...

Page 4: ...has stabilized release the trigger button to hold a temperature reading Upon pressing the trigger button the instrument s secondary display panel will first show the set emissivity and then display th...

Page 5: ...from the area inside the circle While measuring an object the instrument will emit an indicative ring The measured temperature of the surface is the internal temperature of the ring 8 Emissivity Emis...

Page 6: ...zed 0 1 Asbestos 0 95 Asphalt 0 95 Basalt stone 0 7 Carbon 0 8 0 9 Non oxidized 0 7 0 8 Graphite 0 9 Silicon Carbide 0 95 Clay 0 95 Concrete 0 95 Fabric 0 95 Glass plate 0 85 Sand gravel 0 95 Gypsum 0...

Page 7: ...2 Accuracy 0 550 32 1022 1 5 reading 2 50 0 58 32 3 LCD Color LCD D S 12 1 Spectral response 8 14 um Laser 1mW 630 670nm Level 2 Response time 0 5S Automatic shutdown 15S Operating temperature 0 40 St...