LED Display Status
Dual-color LED indicators on the front panel give mainte-
nance personnel quick diagnostics of the operational status of
the MUX. (ref. Fig. 10) Table G explains the LED functions in
detail.
ACK Button
The ACK button performs an LED test. While the ACK but-
ton is held in LEDs will illuminate in their solid color. The
ALARMS LEDs and TL1 PORTS LEDs will alternately blink
red and green.
Hardware Connections
The illustrations on pages 6 and 7 show wiring pinouts for
the MUX.
Craft Port Connector
The Craft Port is a female RS232 DB9 connector used as a
direct link into the MUX. It is normally used to configure or
monitor the MUX. See Fig. 11.
NOTE: When the craft port is in use the MUX port is not ac-
tive.
D-PC-180-10A-XV
5
OG1074A7
November 5, 1997
FA
CRAFT
PORT
A1 A2 A3 A4
1
2
6
4
5
6
7
8
RLY
ACK
ALM
CM1
LOD
ER1
LOC
CFG
DPS INC.
TL1 Mu X-8
ALARMS
TL1 PORTS
Fig. 10 - LED Indicators on the Front Panel Show Operational Status of the TL1 MUX-8
5
4 3
2
1
9
8
7
6
1
2
3
4
5
6
7
8
9
NC
TX
RX
NC
GND
NC
CTS
RTS
NC
Not Connected
Transmit Data
Receive Data
Not Connected
Ground
Not Connected
Clear To Send
Request To Send
Not Connected
PIN # SIGNAL DESCRIPTION
DSR
GND
RTS
CTS
RX
TX
Fig. 11 - Use Craft Port on Front Panel for Configuration