DPS Telecom SCM G2 User Manual Download Page 5

2

Shipping List

3

While unpacking the Site Controller SCM, please make sure that all of the following items are included. If some
parts are missing, or if you ever need to order new parts, please refer to the part numbers listed and call DPS
Telecom at 

(800) 622-3314

.

Site Controller SCM

User Manual

D-PK-SCTRL-12000

D-OC-UM0074.9200

DB9M-DB9F Download Cable 6 ft.

Two ½-Amp GMT Fuse

Four Power/FA/LON Screw Lug Barrier Plugs

One 4-pin Barrier Plug

Four 3-pin Barrier Plugs

19"/23" Rack Ears

Four Rack Screws

Eight 3/8" Ear Screws
and Eight Lock Washers

Summary of Contents for SCM G2

Page 1: ...USER MANUAL Site Controller SCM G2 April 9 2007 D OC UM0074 9200 Visit our website at www dpstelecom com for the latest PDF manual and FAQs Firmware Version v1 0G...

Page 2: ...t as required by United States copyright laws The material in this manual is for information purposes and is subject to change without notice DPS Telecom shall not be liable for errors contained herei...

Page 3: ...twork Connections 4 4 5 Back Panel LEDs 5 6 TTY Interface 6 8 Terminal Interface 6 1 9 Logon 6 2 9 Settings and Timers 6 3 10 Selecting Master and Slave Modes 6 3 1 10 Configure Timers 6 3 2 11 6 3 2...

Page 4: ...e JACE 545 device is a trademark of Tridium Inc The Site Controller SCM has two modes master and slave One master Site Controller SCM connects the JACE Modbus interrogator to the 202 service channel A...

Page 5: ...der new parts please refer to the part numbers listed and call DPS Telecom at 800 622 3314 Site Controller SCM User Manual D PK SCTRL 12000 D OC UM0074 9200 DB9M DB9F Download Cable 6 ft Two Amp GMT F...

Page 6: ...all Standard No 2 Screwdriver Wire Strippers Cutter Computer with TTY Interface Mounting 4 2 Fig 4 1 The Site Controller SCM can be flush or rear mounted The Site Controller SCM can be mounted in a 23...

Page 7: ...attery ground to the GND terminal of the screw lug Seat the barrier screws firmly but be careful not to nick the bare wire Repeat for power source B if you have dual power inputs 4 Push the plug firml...

Page 8: ...Signal Label Wire Color 1 TX T Wht Blu 2 TX R Blu Wht 3 RX T1 Wht Org 4 RX R1 Org Wht Table 4 A Pinout descriptions RJ45 Ethernet Connection 8 7 5 6 Receive In RI 4 3 Receive In RI 2 Transmit Out TO 1...

Page 9: ...displays serial communication to and from the JACE device The SER LED will BLINK GREEN when the Site Controller SCM is TRANSMITTING data to the JACE device and BLINK RED when the Site Controller SCM i...

Page 10: ...ER Blink Green Transmitting data on the JACE serial port Off No DCD seen from another Site Control Manager 3 C Carrier Green Indicates DCD is seen from another Site Control Manager Blink Red Receiving...

Page 11: ...software such as Windows HyperTerminal To open HyperTerminal start from your Windows Start menu and go to Programs Accessories Communications HyperTerminal 3 The Connection Description prompt will app...

Page 12: ...the parenthesis For example to select the C onfig menu from the main menu press C To E xit the terminal interface press E To quit a menu press Esc and you will return to the previous menu Configuratio...

Page 13: ...timeout interval To configure your settings press C Config in the main menu then press S Settings 6 3 1 Selecting Master and Slave Modes Fig 6 6 Select Master mode from Settings menu Use the followin...

Page 14: ...time range is 0 255 msec 6 3 2 2 RTS Tail Time Fig 6 8 Press T in the C onfig S ettings menu to configure RTS Tail time The C onfig S ettings T ail command opens options for setting the RTS tail time...

Page 15: ...msec The Poll Wait Time command works differently under Slave and Master modes When the Site Controller SCM is set to Slave mode the timeout refers to communication between the Site Controller SCM and...

Page 16: ...a confirmation prompt will ask you to confirm your choice see Figure 6 12 Note Initializing the NVRAM will erase all configuration information Do not initialize the NVRAM unless you want to re enter a...

Page 17: ...ansmit level ten increments higher 8 Transmit continuous alternating mark and space tones on the modem output line This is the equivalent of sending the ASCII character U hex 0x55 Table 6 A Tune modem...

Page 18: ...nit to become inoperable While uploading the ComloaderW screen will display the checksum type and phase of the task file and the baud rate of your connection to the Site Controller SCM The progress ba...

Page 19: ...ftware is detected 2 ALL RED when waiting for DPSLOAD signal 3 ALL GREEN when DPSLOAD signal received 4 SLOW 1 LED step every 1 5 seconds RED LED walk while flash memory is wiped Each LED step means 1...

Page 20: ...17 Technical Support 8 For technical support questions please call Tridium Inc directly at 1 804 747 4771 or visit their website at www tridium com...

Page 21: ...18...

Page 22: ...19...

Page 23: ...lightning unless and to the extent that the product specification provides for resistance to a defined disaster e damage caused by unauthorized attachments or modifications f damage during shipment f...

Page 24: ...and gives you exclusive access to Firmware and software downloads and upgrades Product manuals Product datasheets Exclusive user forms Register for MyDPS online at Expert tips on using your alarm mon...