A-3
RPO3 Operation & installation manual.doc 12/18
INSTALLATION AND SERVICE
Installation and service must be done by specialized technicians. Contact a certified electrician and
plumber for set up.
The oven must be connected to the utility and electrically grounded in conformity to the effective
local regulations. If these are not established, the oven must be connected according to the Canadian
Electrical Code (CSA-C22.1-XX) or National Electrical Code (NFPA 70-XX). Refer to last edition
year for XX. Installation must also
allow proper access for service
(24 inches each side and back).
The ovens must be installed with a proper ventilation according with the local building code.
A)
Back and sides of the oven: 1 inch.
B)
Top of the oven: a clearance of 12 inches to the ceiling must exist to permit adequate venting.
C)
Counter top: 4 inches minimum of counter top surface( with legs).Or seal flush with counter top
D)
Sides of the oven: do not install other than easily removable equipment for service and
maintenance (not closer than 1 inch).
E)
It is recommended to have a certain length of water pipe, electric cable between oven and
wall to help gain access for service.
INSTALLATION WARNINGS
POWER FAILURE WARNING
WHEN YOU HAVE A POWER FAILURE, SHUT OFF THE OVEN POWER SWITCH TO
PROTECT THE ELECTRONIC COMPONENTS WHEN THE POWER COMES BACK.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY APPLIANCE.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.
READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
WARNING
--RISK OF ELECTRICAL SHOCK--
APPLIANCE MUST BE SECURED TO BUILDING STRUCTURE, SEE PAGE A5
DISTANCES TO RESPECT