RPO3 Operation & installation manual.doc 12/18
A-8
Manual mode display Icon description
:
Speeds
Fan speed LOW. Press the icon to toggle between desired speeds.
Fan speed MEDIUM
DEFAULT Fan speed HIGH
Air flow
When this icon is displayed icon is displayed, the fan is pushing air forward
When this icon is displayed icon is displayed, the fan is pushing air backwards
When this icon is displayed icon is displayed, the fan will alternate the flow of air in the oven’s cavity
FAN SPEED FUNCTION
You can change the fan speeds. There are 3 different fan speed setting available LOW, MEDIUM and HIGH, Default
speed is HIGH To select a different fan speed press the fan speed icon to select desire fan speed. This function will
creating a different air flow.
JET AIR FUNCTION
3 different Default fan reversing cycles setting available 1 (2.5 min ON - 25 sec. OFF), 2 (1.5 min ON - 10 sec OFF),
and 3 (2.5 min ON - 10 sec. OFF). Fan reversing is set to 1 default, to select a different fan reversing cycle, press the
fan reversing cycle icon to select desired fan reversing cycle time.
This function will change the fan reversing time cycle, creating a different air flow volume during the baking.