A-7
PROOFER OPERATION
!
DPW10, DPW10S, DPW10HP, DPW10HPS
Insulated proofer warmer. 90°F to 180°F, automatic and manual water fill.
1.
Fill the water pan with soft water or connect the building cold water to the unit. The water pan
capacity : 2 litter, (½ us gallon)
2.
Turn the switch to the right for proofer mode and to the left for warmer mode.
3.
Set the thermostat control at 90° - 100°F for proofer mode.
Set the thermostat control at 150°
- 180°F for warmer mode.
4.
In proofer mode, set the humidity control at 4 1/2. (it takes
approximately 35 minutes for preheat).
5.
When the temperature is stabilized, put the products in the
cabinet.
6.
IMPORTANT:
When proofing cycle is completed, turn the
humidity switch to "OFF" and let the blower and air heat element
run for 10-15 minutes (with door open) to let dry the proofer.
Then, turn the main switch ‘’OFF’’ (0) and leave the door ajar to
prevent molding.
When the proofer is not in operation, open the door to let out the humidity and then prevent
mold.
P.S.
During operation, the doors should not be opened unnecessarily to conserve the heat and
humidity in the proofer.
Every day cleaning of the water pan under the proofer's doors should be exercised.
USE SOFT WATER ONLY.
Cleaning the water pan in the proofer periodically can prevent mineral problems.
POWER FAILURE
When the power comes back, the proofer will start automatically. If the power failure, it’s
recommended to turn OFF the unit to avoid it starting without supervision.