BTF080/ BTF100/ BTF120/ BTF140-E1R2
Page 15
B – State: in function
c
Inactive button.
d
If
d
is in “0” (zero) on start, the time showed during the work is ascending and is incremented until
the machine stops or it will automatically stop when 99 minutes and 99 seconds in
d
is reached.
If
d
is in “0” (zero) on start, the time showed during the work is decreasing and will be incremented.
The machine stops automatically when it reaches time “0” (zero) in
d
.
If
d
is in work, it will be ascending and adjusted to a superior value, it automatically begins to
decrease. In the same way, it can happen in the inverse situation, if
d
is decreasing and is
adjusted to an inferior value, it automatically starts to grow.
e
Display with the function defined in “A”.
Can be changed during the work.
f
Button to access the function defined in “A”.
g
Button to access the function defined in “A”.
h
Button to access the function defined in “A”.
i
Button to access the function defined in “A”.
j
Button to access the rising of the bowl’s arm (when applicable).
k
Button to access the descent of the bowl’s arm (when applicable).
cb
Button to access the function “pause” in work. It maintains the time and velocities unchanged.
To restart the work, press “C”
cb
.
cc
Button to access the function “stop” in work.
It stops the work and puts to zero the time in course in
d
.
This button appears automatically after the machine initiates the work.
cd
Space reserved with function defined in “A”.