13
6 Electrical Connection
IPack C6.5 can work in single mode and parallel mode. To make the battery work properly, follow the
instructions below to correctly connect it.
This chapter describes how to make cable and wires, and connect one battery and multiple batteries. If you
6.1 Power Terminals and Network Ports
Terminal
Model
Cable Cross-Section
+
Amphenol, C10-752799-010
25 mm²
-
Amphenol, C10-752799-110
25 mm²
M6 HEX socket head cap screw
16 mm²
No.
PCS
Link-Out
Link-In
1
PCS-RS485-B
PACK-CANH
PACK-CANH
2
PCS-RS485-A
PACK-CANL
PACK-CANL
3
NC/GND-ISO
Encode-OUT+
Encode-IN+
4
PCS-CANH
GND-ISO
GND-ISO
5
PCS-CANL
Slave-Last
Master-Select
6
NC/GND-ISO
GND-ISO
GND-ISO
7
PCS-WAKE-
GND-ISO
NG/GND-ISO
8
PCS-WAKE+
COM-WKP-OUT COM- WKP-OUT
6.2 Prepare Cables
Step 1.
Make power cables.
Joint Sleeve
Sealing
Sealing Nut
1.
Strip cable sheaths for 20±0.5mm and insert sealing
and sealing nut along the cable.
Orange: positive cable
Black: negative cable
2.
Insert the copper wires all into the joint sleeve.
1
8
1
8
1
8
1
8