Appendix 1: Technical data
Model
ZEN
Nominal output
4.75 kW
Flue connection (diameter)
150 mm
Weight
100 -115 kg
Recommended fuel
Wood
Fuel property, max. length
30 cm
Mass flow of flue gasses
5.1 g/s
Flue gas temperature measured in the measurement section
198 °C
Temperature measured at appliance exit
247
℃
Minimum draught
12 Pa
CO emission (13%O
2
)
0.09 %
NOx emission (13% O
2
)
111 mg/Nm³
CnHm emission (13%O
2
)
238 mg/Nm³
Particulate emission
293 mg/Nm³
Particulate emission in accordance with NS3058-NS3059
4.76 g/kg
Efficiency
80.1 %
18
Subject to change because of technical improvements