9. Declared performance:
The harmonised norm
EN 13229:2001/A2 ;2004/AC :2007
Essential characteristics
Performance Wood
Fire safety
Fire resistance
A1
Distance from combustible material
Minimum distance in mm
Rear: 50 with insulation
Side: 60 with insulation
Risk of glowing particles falling out
Conform
Emission of combustion products
CO: 0.09% (13%O
2
)
Surface temperature
Conform
Electrical safety
-
Ease of cleaning
Conform
Maximum operating pressure
-
Flue gas temperature at nominal output
175 °C
Mechachanical resistance (weight carry of chimney)
Not determined
Nominal output
4.75 kW
Efficiency
80.1 %
10. The performance of the product described in points 1 and 2 conform with the performance reported
in point 9.
This performance declaration is supplied under the exclusive responsibility of the producer specified
in point 4:
10/02/2014 Weelde
Tom Gehem
CEO
Due to continuous product improvement, the supplied appliance specifications may vary from the description in
this brochure without prior notice having been given.
DOVRE N.V.
Nijverheidsstraat 18
Tel : +32 (0) 14 65 91 91
B-2381 Weelde
Fax : +32 (0) 14 65 90 09
Belgium
E-mail : [email protected]
Subject to change because of technical improvements