![Dovre VISTA 700i Installation Instructions & Operating Manual Download Page 16](http://html1.mh-extra.com/html/dovre/vista-700i/vista-700i_installation-instructions-and-operating-manual_2525178016.webp)
16
Subject to change because of technical improvements
length (12 m) must be reduced by 1 m for each access-
ory used.
1
2
A
B
09-200021-235
If you decide to use the outside air connection (A) or
(B), you must use the two screws (1) to attach the
provided cover plate (2) for closing off the inside air.
3
4
A
B
A6
B6
5
+
1
2
09-200021-236
The outside air connection can be placed underneath
or at the back.
1. Break the relevant cover from (A) at the back or
(B) underneath.
2. Disassemble all removable interior parts as men-
tioned previously.
3. Remove the fan plate (4) in the back wall of the
appliance by loosening the screws (3).
Be careful with the electrical wiring and the
fans.
4. Assemble the collar (5) at the back (A6) or under-
neath (B6) using cord and the provided bolts.
5. Seal the pipe hermetically (airtight) to the collar.
6. Re-position the fan plate, and re-position the cable
housing in its position.
Be careful with the electrical wiring and the fan.
Finishing
1. Re-position all removed parts in the correct places
in the appliance.
2. Ensure that the newly built hearth is sufficiently
dry before you start to use the appliance.