D
OVRE
Subject to change because of technical improvements
25
Eco mode
09-20021-391
ON
: Press the [
Eco
] key to launch the Eco mode; the
symbol appears on the display.
OFF
: Press the [
Eco
] key to exit the Eco mode; the
symbol disappears from the display.
Manual operation
Manual operation of the stove is only possible if the
MAN button is used, see the following figure.
1
2
3
4
5
6
7
8
09-20020-244
1
Piezo ignition (option)
2
On/off switch (option)
3
Eight-wire-receiver-contact
4
Microswitch
5
Piezo ignition connection (2.8x0.8mm)
6
Manual button in
MAN
position
7
Manual pilot regulator
8
Main valve button in
OFF
position
Access to the pilot is only required for igniting
with a match.
Do not exert excessive force when turning the
main valve button. The button has a slip-action
clutch that clicks until the final stops are
reached. This enables manual programming of
the flame height and the pilot standby position.
Read the safety information before continuing.
1. Turn the main valve button (8) to the
OFF
position,
completely clockwise
.
2. Turn the MANUAL button (6) to the
MAN
position,
completely clockwise
.
A manual pilot regulator and Piezo ignition
(option) are accessible when the MAN button
is in the
MAN
position.
3. Wait five minutes until the stove is free of gas.