OM-HY/6G(CE) 11
Initial Start-Up
11.
Automatic Operation of Pilot
Once the pilot burner is lit, it essentially functions as a standing pilot. In this state,
if the pilot is accidentally extinguished (by a very strong gust of wind for example),
it will re-ignite automatically. The unit will completely shut down for a few seconds
while the pilot is re-ignited.
Then the unit will come back on and resume operation in the mode and with the
(running) timer value existing just prior to shutdown. The pilot switch may be
turned off during “off hours” to conserve energy.
After the unit has been running, if the pilot burner ever fails to re-ignite
automatically within 90 seconds, wait 5 minutes before you attempt to reactivate
it. In the unlikely event that ignition problems persist, contact your authorized
Groen Service Agency.
NOTE: For operation at high altitudes (2000 feet and above) please consult the
Groen Food Service Engineering Department.
12.
Gas Type Conversion
(See Paragraph 3 on page 9 for important information for gas
conversion. Verify the type of gas to be used).
To change the type of gas used (e.g. G20 to/from G31) change the following:
Burner injector, Pressure setting on Main Gas Valve, Data plate, Gas pressure
Regulator Springs
The governor spring does not need to be changed; only the pressure setting.
ALL CONVERSIONS MUST BE FOR APPROVED GAS IN THE COUNTRIES LISTED IN
PARAGRAPH 3 ON PAGE 9.