Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation
parameters will fall in the center of the pump's performance curve.
PS1520/PS1530 METAL
EZ-INSTALL TPE-FITTED
1520 Threaded AL .................. 69 kg (152 lb)
1520 Threaded SS ............... 126 kg (278 lb)
1520 Threaded Iron .............. 114 kg (251 lb)
1530 Flanged AL ...................101 kg (223 lb)
1530 Flanged SS ................. 137 kg (300 lb)
1530 Flanged Iron ............... 124 kg (272 lb)
Air Inlet .................................................. 3/4”
Inlet ............................................ 76 mm (3”)
Outlet ......................................... 76 mm (3”)
Suction Lift .................. 6.4 m Dry (21.1’) AL
9.0 m Wet (29.5’) AL
5.4 m Dry (17.6’) SS
8.6 m Wet (28.4’) SS
5.2 m Dry (17.0’) Iron
9.7 m Wet (31.8’) Iron
Disp. per Stroke
1
............ 5.1 L (1.35 gal) AL
5.4 L (1.43 gal) SS
5.1 L (1.34 gal) Iron
Max. Flow Rate .......... 1026 lpm (271 gpm)
Max. Size Solids ..................12.7 mm (1/2”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 337 lpm (89 gpm)
against a discharge head of 2.8 bar (40
psig) requires 4.1 bar (60 psig) and 85
Nm
3
/h (50 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation
parameters will fall in the center of the pump's performance curve.
PS1520/PS1530 METAL
RUBBER-FITTED
1520 Threaded AL .................. 69 kg (152 lb)
1520 Threaded SS ............... 126 kg (278 lb)
1520 Threaded Iron .............. 114 kg (251 lb)
1530 Flanged AL ..................101 kg (223 lb)
1530 Flanged SS ................. 137 kg (300 lb)
1530 Flanged Iron ............... 124 kg (272 lb)
Air Inlet .................................................. 3/4”
Inlet ............................................ 76 mm (3”)
Outlet ......................................... 76 mm (3”)
Suction Lift ...................7.2 m Dry (23.8’) AL
9.0 m Wet (29.5’) AL
6.0 m Dry (19.7’) SS
8.6 m Wet (28.4’) SS
6.7 m Dry (22.1’) Iron
9.7 m Wet (31.8’) Iron
Disp. per Stroke
1
............ 5.1 L (1.35 gal) AL
5.0 L (1.32 gal) SS
5.0 L (1.31 gal) Iron
Max. Flow Rate .......... 1026 lpm (271 gpm)
Max. Size Solids ..................12.7 mm (1/2”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 700 lpm (185 gpm)
against a discharge head of 1.4 bar (20
psig) requires 5.5 bar (80 psig) and 161
Nm
3
/h (95 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.