WIL-11251-E-03
9
P800 Bolted Plastic
SECTION 5
P800 PLASTIC
RUBBER-FITTED
Ship Weights.……Polypropylene 32 kg (70 lb)
PVDF 45 kg (99 lb)
Air Inlet…………..………………..13 mm (1/2")
Inlet…...……………...………………51 mm (2")
Outlet………………...………………51 mm (2")
Suction Lift….………………6.23 m Dry (18.5’)
8.65 m Wet (28.4’)
Disp. per Stroke
1
……..….......2.75 L (0.73 gal)
Max. Flow Rate……………624 lpm (165 gpm)
Max. Size Solids……………......6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2 bar (30
psig) head pressure.
Example:
To pump 246 lpm (65 gpm)
against a discharge head pressure of
2.8 bar (40 psig) requires 4.1 bar (60 psig)
and 85 Nm
3
/h (50 scfm) air consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
P800 PLASTIC
TPE-FITTED
Ship Weights.……Polypropylene 32 kg (70 lb)
PVDF 45 kg (99 lb)
Air Inlet…………..………………..13 mm (1/2")
Inlet…...……………...………………51 mm (2")
Outlet………………...………………51 mm (2")
Suction Lift….……………..5.54 m Dry (18.16’)
8.66 m Wet (28.4’)
Disp. per Stroke
1
……..….......2.85 L (0.74 gal)
Max. Flow Rate……………615 lpm (162 gpm)
Max. Size Solids……………......6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2 bar (30
psig) head pressure.
Example:
To pump 322 lpm (85 gpm) against
a discharge head pressure of1.2 bar (17 psig)
requires 2.8 bar (40 psig) and 85 Nm
3
/h (50
scfm) air consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
PERFORMANCE