WIL-10150-E-11
Wilden
®
9
PERFORMANCE
P2 PLASTIC
REDUCED-STROKE
PTFE
-FITTED
Ship Weight ......... Polypropylene 8 kg (18 lb)
PVDF 10 kg (23 lb)
Air Inlet ....................................... 6 mm (1/4")
Inlet. ...........................................25 mm (1")
Outlet .......................................... 25 mm (1")
Suction Lift ............................ 3.4 m Dry (11')
8.8 m Wet (29.0')
Disp. Per Stroke
1
.................. 0.23 L (0.061 gal)
Max. Flow Rate ............... 132 lpm (35 gpm)
Max. Size Solids ...................... 3.2 mm (1/8")
1
Displacement per stroke was calculated
at 4.8 Bar (70 psig) air inlet pressure against
a 2 Bar (30 psig) head pressure.
Example:
To pump 68 lpm (18 gpm)
against a discharge pressure head of
2.7 bar (40 psig) requires 4.1 bar (60 psig)
and 37.2 Nm
3
/h (22 scfm) air consumption.
(See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
P2 PLASTIC
FULL-STROKE
PTFE
-FITTED
Ship Weight ......... Polypropylene 8 kg (18 lb)
PVDF 10 kg (23 lb)
Air Inlet ....................................... 6 mm (1/4")
Inlet. ...........................................25 mm (1")
Outlet .......................................... 25 mm (1")
Suction Lift ..........................
4.1m Dry (13.6’
)
8.6 m Wet (28.4’)
Disp. Per Stroke
1
...................... 0.6 L (0.15 gal)
Max. Flow Rate ............ 139 lpm (36.8 gpm)
Max. Size Solids ...................... 6.4 mm
(1/4”)
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2.1 bar (30 psig) head pressure.
Example:
To pump 98.4 lpm (26 gpm)
against a discharge head of 1.4 bar
(20 psig) requires 5.5 bar (80 psig)
and 61 Nm
3
/h (38 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.