WIL-10150-E-11
Wilden
®
8
PERFORMANCE
P2 PLASTIC
RUBBER
-FITTED
Ship Weight ......... Polypropylene 8 kg (18 lb)
PVDF 10 kg (23 lb)
Air Inlet ....................................... 6 mm (1/4")
Inlet. ...........................................25 mm (1")
Outlet .......................................... 25 mm (1")
Suction Lift ......................... 5.5 m Dry (18.0')
8.8 m Wet (29.0')
Disp. Per Stroke
1
.................. 0.31 L (0.082 gal)
Max. Flow Rate ............... 140 lpm (37 gpm)
Max. Size Solids ...................... 3.2 mm (1/8")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2 bar (30 psig) head pressure.
Example:
To pump 68 lpm (18 gpm)
against a discharge pressure head of
2.7 bar (40 psig) requires 4.1 bar (60 psig)
and 21.9 Nm
3
/h (13 scfm) air consumption.
(See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
P2 PLASTIC
TPE
-FITTED
Ship Weight ......... Polypropylene 8 kg (18 lb)
PVDF 10 kg (23 lb)
Air Inlet ....................................... 6 mm (1/4")
Inlet. ...........................................25 mm (1")
Outlet .......................................... 25 mm (1")
Suction Lift ......................... 5.5 m Dry (18.0')
8.8 m Wet (29.0')
Disp. Per Stroke
1
.................. 0.39 L (0.104 gal)
Max. Flow Rate ............... 140 lpm (37 gpm)
Max. Size Solids ...................... 3.2 mm (1/8")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2 bar (30 psig) head pressure.
Example:
To pump 68 lpm (18 gpm)
against a discharge pressure head of
2.7 bar (40 psig) requires 4.1 bar (60 psig)
and 18.6 Nm
3
/h (11 scfm) air consumption.
(See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
Section 5
Summary of Contents for PSG Wilden PRO-FLO P2
Page 27: ...WIL 10150 E 11 Wilden Notes ...