Disassembly / Reassembly
Step 7
With a 1/2" box wrench, loosen the large clamp bands that
secure the liquid chambers to the center section.
Step 8
Rotate the clamp bands so that they can be removed.
Step 9
After clamp bands are removed, pull liquid chambers apart.
Step 10
Remove tee section from liquid chamber and inspect O-rings for
signs of wear. Replace worn parts with genuine Wilden parts for
reliable performance.