![Dover PSG Wilden P1 Engineering, Operation & Maintenance Download Page 9](http://html1.mh-extra.com/html/dover/psg-wilden-p1/psg-wilden-p1_engineering-operation-and-maintenance_2525030009.webp)
WIL-10140-E-08
Wilden
®
9
PERFORMANCE
P1 PLASTIC
PTFE
-FITTED
Height .................................... 218 mm (8.6")
Width ...................................... 208 mm (8.2")
Depth ..................................... 203 mm (8.0")
Est. Ship Weight ... Polypropylene 4 kg (9 lbs)
PVDF 5 kg (11 lbs)
PTFE PFA 6 kg (12 lbs)
Air Inlet....................................... 6 mm (1/4")
Inlet ....................................... 13 mm (1/2")
Outlet ...................................... 13 mm (1/2")
Suction Lift ....................... 5.18 m Dry (17')
9.8 m Wet (32')
Disp. Per Stroke
1
.................. 0.10 l (0.027 gal.)
Max. Flow Rate ........... 53.4 lpm (14.1 gpm)
Max. Size Solids .................... 1.6 mm (1/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2 bar (30 psig) head pressure.
Example:
To pump 18.9 lpm (5 gpm)
against a discharge pressure head of
2.8 bar (40 psig) requires 3.9 bar (56 psig)
and 6.93 Nm
3
/h (4.1 scfm) air consumption.
(See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump performance curve..