Dover PSG Mouvex CENTREX MULTI 2M Installation Operation & Maintenance Download Page 7

7/11

NT 1006-C00 03 18 Centrex Multi 2  e

3.1 No return valve item 15 calibration

The No return valve item 15 is available with 2 values of
calibration to select when the order of the complete unit
is placed :

• 0,1 bar calibration : storage in an above ground tank

• 0,4 bar calibration : storage in an under ground tank

3.2 Pipe diameter

It is important to take the following recommendations :

Head loss :
• The pipe diameter is chosen as a function of its length,

the flow rate and the viscosity of the pumped product.
However, it is never a disadvantage to over-dimension
the inlet pipe diameters.

• Generally, the discharge pipe diameter(s) is a diameter

equal to the ports of the pump.

Our Technical Services are always available to provide
you with precise data if you give them accurate informa-
tion or, better still, the installation plans.

3.3 Piping assembly

It is important to take the following recommendations :

• The location of the pump in the circuit should always be

determined so as to reduce the height and length of the
piping as much as possible particularly when used for
suction.

• Wherever possible, siphons and reverse slopes should

be avoided in the inlet piping.

• Particular care needs to be taken with the sealing on

the inlet side to prevent air entering.

• Pipe elbows must always have a large radius (more

than 3 times the diameter of the pipes) and must not be
mounted too close to the pump flanges (min. recom-
mended distance : 10 times the diameter of the pipes),
on both the inlet and discharge sides.

• The pipes are supported and aligned with the pump in

such a way as to avoid putting stress on the pump flan-
ges. Non-compliance with this instruction can lead to
deformation of pump parts, misalignment of bearings
and accelerated material wear, even causing parts to
break.

• The CENTREX MULTI, Turbine version, is delivered with

the discharge piping module disconnected. That allows
to reduce the dimensions and in consequence to mini-
mize the packaging size. This module has to be connec-
ted (already tested in our workshop), please make sure
the pipe is properly supported in order to avoid any
vibrations creation as well tension on the unit.

• We recommend placing valves as close as possible to

the pump ports to avoid having to drain the entire sys-
tem each time maintenance is carried out. These val-
ves should have the same diameter as the pipes and
preferably by full bore models.

• Before installing new pipes or tanks, be sure to clean

them very carefully to remove any solder, rust, etc.
which could be carried along with the water and cause
excessive pump wear.

• The pipes should be designed to allow for thermal

expansion/contraction (the use of flexible hoses or
expansion loops is recommended).

• If the liquid may freeze or solidify, prepare for draining

the piping by installing drain taps at the low points and
air vents at the high points.

3.4 Degassing

The gases caught by the gas separator are sent in the
discharge line 

7

, downstream to the meter without distur-

bing the operation and the accuracy of the unit.

No connection is necessary.

3.5 Direction of rotation

The pump and unloading unit are not reversible. Ensure
that the motor is connected correctly according to the
pump's direction of rotation, indicated by arrows on the
body.

WARNING

OPERATION WITHOUT THE SHAFT
PROTECTOR CAN CAUSE SERIOUS
PERSONAL INJURY, MAJOR PROPER-
TY DAMAGE OR DEATH.

Do not operate

without guard 

in place.

3. INSTALLATION

WARNING

FAILURE TO RELIEVE THE SYSTEM
PRESSURE PRIOR TO PERFORMING
ANY WORK ON THE PUMP OR THE
INSTALLATION CAN CAUSE PERSONAL
INJURY OR PROPERTY DAMAGE.

Hazardous pressure 

can cause 

personal injury 

or property damage.

WARNING

SYSTEM FITTINGS AND HOSES MUST
BE CAPABLE OF WITHSTANDING
OPERATING PRESSURES.

Hazardous pressure 

can cause 

personal injury 

or property damage.

Summary of Contents for PSG Mouvex CENTREX MULTI 2M

Page 1: ...Version 3 Your distributor Z I La Plaine des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex com www mouvex com WARRANTY CENTREX MULTI 2 units are covered 24 months by warranty within the limits mentioned in our General Sales Conditions In case of a use other than that mentioned in the Instructions manual and without preliminary agreement of MOUVEX warrant...

Page 2: ... MOUVEX CENTREX MULTI 2 units must ONLY be carried out by qualified technicians This maintenance must meet local and national standards as well as all safety regulations Read this manual including all instructions and warnings in full BEFORE any use of MOUVEX CENTREX MULTI 2 units Do not remove the warning and use label stickers that are found on the compressors ADDITIONAL DOCUMENTATION The table ...

Page 3: ...den crosspieces after installation Fork zone WARNING PUMPS OPERATING AGAINST A CLO SED VALVE CAN CAUSE SYSTEM FAILURE PERSONAL INJURY AND PROPERTY DAMAGE Hazardous pressure can cause personal injury or property damage WARNING OPERATION WITHOUT THE SHAFT PROTECTOR CAN CAUSE SERIOUS PERSONAL INJURY MAJOR PROPER TY DAMAGE OR DEATH Do not operate without guard in place WARNING DISCONNECTING THE FLUID ...

Page 4: ...ENTREX MULTI 2 T 0 7 0DQRPHWUH 3UHVVXUH JDXJH 9LVHXU 6LJKW JODVV FKHFN SRXU DQFUDJH 0 IRU DQFKRUDJH 0 ULGH ODQJH 6 DO RX RU 2SWLRQ YDQQH YRLHV 7XEH j VRXGHU 237 21 PHWWHXU 62 RX HPHWWHXU 9HHGHU 5RRW 0RWHXU 7 9 RX 7 N 3 3LHG UpJODEOH GMXVWLQJ IRRW 3XUJH UHWRXU SURGXLW UDLQ 5 6 1 DYHF ERXFKRQ 6QDS FRXSOLQJ 1 ZLWK SOXJ 237 21 PSULPDQWH 3ULQWHU 5HWRXU GpJD DJH HJDVVLQJ UHWXUQ OLQH RSWLRQ 0 7 RPSWHXU 0...

Page 5: ...signals depending on the version Once the compartment is empty the assembly will fill with air and the meter will stop If the next compartment contains the same product connect the DN80 hose to it without stopping the pump If the next compartment contains another product Lift the DN80 hose to drain it and wait for the meter to stop and the gas separator sight glass 17 to empty Print the ticket wher...

Page 6: ...to zero 2 2 Operating characteristics Nominal flowrate 60 m3 h Maximal differential pressure 4 bar Maximum vacuum allowed 0 3 bar Running temperature 10 to 50 C The noise generated by the CENTREX unit under normal operating conditions 80 dBA Minimum delivery 500 litres Accuracy of the metering unit 0 4 Repeatability 0 05 2 3 Operation The operator should remain nearby the equipment through out the ...

Page 7: ...ULTI Turbine version is delivered with the discharge piping module disconnected That allows to reduce the dimensions and in consequence to mini mize the packaging size This module has to be connec ted already tested in our workshop please make sure the pipe is properly supported in order to avoid any vibrations creation as well tension on the unit We recommend placing valves as close as possible t...

Page 8: ...st be protected by appropriate circuit breakers and fuses Connect the regulatory ground connections Check the direction of rotation This check should be done with no product being pumped and both the inlet and discharge circuits vented to avoid generating unexpected pressure on the inlet side for example This will avoid damaging either the pump or the system WARNING OPERATION WITHOUT THE SHAFT PRO...

Page 9: ...E OPERATION Toxic or hazardous fluids can cause serious injury 5 PRODUCTS UNLOADED Start the pump empty to check that the connections are good and that the direction of rotation corresponds to the system intake and discharge directions If it is necessary to reverse the direction of rotation follow the instructions below Three phase motor switch any 2 current input wires Ensure to remove the draini...

Page 10: ...ORK IMPOSSIBLE Any unforeseen start up can cause serious injuries or important material damages WARNING BE CAREFUL WITH THE WEIGHT OF THE PARTS WHEN THEY ARE BEING REMOVED The weight ot the parts can be dangerous and may provoke bodily injuries or material damages WARNING HYDRAULIC PRESSURE MUST BE FULLY RELEASED BEFORE MAINTENANCE OPERATIONS IN ORDER TO PREVENT PERSONAL INJURY OR PROPERTY DAMAGE ...

Page 11: ...ngen bezogen auf mechanische und elektrische Risiken die für rotierende Maschinen gelten NF EN 809 2009 NF EN 1672 2 2009 NF EN ISO 13857 2008 NF EN 12162 2009 ATEX Richtlinie 2014 34 EU 26 Feb 2014 wie umgesetzt im nationalen Recht in Bezug auf Ausrüstungen für den Einsatz in explosionsgefährdeter Atmosphäre Die Konformität hat Geltung durch Anwendung folgender Normen NF EN 1127 1 1997 NF EN 1346...

Reviews: