12/19
NT 1003-A00 09 18 AZ O e
6. BYPASS (continued)
6.3 Inversion
Before commencing work, make sure that the pump
cannot be started up, even accidentally. Before opening
the pump, it must be drained and relieved of any pressu-
re it may contain. Take care to check that the isolation
valves, if any, are closed before pulling out the drain
plug
812
and its seal
848
.
To reverse the bypass, remove the nut
808
and the set
of parts
805
-
806
-
807
-
809
and
810
. Remove the
valve
803
, its spring
804
and fit those parts on the oppo-
site side.
Fit the plug
812
and the seal
848
in the place of the nut
808.
6.4 Adjustment
To adjust the bypass, unscrew the cap
810
and its seal
809
, turn the adjustment screw
806
clockwise to increa-
se the discharge pressure, and anticlockwise to decrea-
se it. Once the adjustment is finished, do not forget to re-
screw the cap
810
and its seal
809.
Adjustment of the bypass is satisfactory when the flow
meets the pumps requirements and when the motor
bears the power increase due to the overpressure seen
upon closing the discharge. This is how the bypasses of
our pump units are adjusted, as a function of the infor-
mation provided by our Technical Services.
The pumps supplied bare shaft are delivered with a
standard bypass setting which needs to be adjusted with
the exact working conditions and installation, as per the
above described procedure.
WARNING
FAILURE TO RELIEVE SYSTEM
PRESSURE PRIOR TO PERFORMING
PUMP SERVICE OR MAINTENANCE
CAN CAUSE PERSONAL INJURY OR
PROPERTY DAMAGE.
Hazardous pressure
can cause
personal injury
or property damage.
WARNING
PUMPS OPERATING AGAINST A CLO-
SED VALVE CAN CAUSE SYSTEM
FAILURE, PERSONAL INJURY AND
PROPERTY DAMAGE.
Hazardous pressure
can cause
personal injury
or property damage.
WARNING
IF PUMPING HAZARDOUS OR TOXIC
FLUIDS, THE SYSTEM MUST BE FLUS-
HED PRIOR TO PERFORMING ANY
SERVICE OPERATION.
Hazardous or toxic
fluids can cause
serious injury.
WARNING
DISCONNECT THE ELECTRICITY
SUPPLY BEFORE ANY MAINTENAN-
CE OPERATION.
Dangerous voltage.
Can cause
injury and death.
WARNING
BE CAREFUL WITH THE WEIGHT OF
THE PARTS WHEN THEY ARE BEING
REMOVED.
The weight ot the parts
can be dangerous and
may provoke bodily inju-
ries
or material damages.
Loading (bar)
Mini
Maxi
1,65
5