![Dover Mouvex SLC24 Installation Operation & Maintenance Download Page 22](http://html1.mh-extra.com/html/dover/mouvex-slc24/mouvex-slc24_installation-operation-and-maintenance_2524991022.webp)
22/23
NT 1004-C00 09.09 SLC24 SLC36 e
• Drain the transmission following the board below :
•
Data with standard MOUVEX oil :
•
Data with other customer oil :
the drawing interval is
defined by the customer (tests results) regarding the oil
specifications and the pump conditions.
• Drain the pump by removing the drain bung with its
seal
773-774
and the breather
715
.
• Replace the drain bung and its seal.
• Fill the transmission with 4,5 litres of oil*.
• Check oil level that the level is between 1 and 5 mm above
the schaft.
• Screw back the breather
715
.
* Standard oil provided by MOUVEX : CS05 Food synthe-
tic oil (Safety data sheet is supplied with the new pump
and on inquiery)
.
*
Other oil provided by customer.
Oil level
Min : 1 mm
Max : 5 mm
Temperature of product
pumped / heating product
Draining interval
(running hours)
80 °C < T ≤100 °C
12 000
T ≤ 80 °C
24 000
THE PUMP LUBRICANT IS VERY SLIPPE-
RY AND MAY CAUSE SERIOUS INJURY.
ANY SPILLS MUST BE CLEANED UP.
CAUTION
Slippery lubricant.
Spills should be
cleaned up.
11. DRAINING OF BEARING