![Dover Mouvex SLC24 Installation Operation & Maintenance Download Page 16](http://html1.mh-extra.com/html/dover/mouvex-slc24/mouvex-slc24_installation-operation-and-maintenance_2524991016.webp)
16/23
NT 1004-C00 09.09 SLC24 SLC36 e
6.1 ASSEMBLY / DISMANTLING
• Disconnect the pump from the discharge pipe.
• Unscrew and remove the 6 studs-nuts
105-106
and the
two studs-nuts
105-107
.
• Remove the front cover
401
with the 2 screwdrivers.
If the discharge piping is mounted in a rigid manner,
pivot the bottom
401
so as to free the connection.
• Remove the seal
205
.
• Hold the piston
301
with a 85 Open-end spanner or a mon-
key wrench and unscrew the nut
304
and its seal
305
.
• To make handling of the cylinder/piston unit easier, move
the lifting ring from the transmission body to the cylinder
.
• Screw the lifting hook in the tapped hole of the cylinder,
provided for this purpose and tighten the screw in the
location of the lifting ring.
401
It is important to keep a good grip on the
piston, its rotation could lead to deterioration
of the bellows.
Before any dismantling, make sure that the
pump has been drained and take the neces-
sary measures to avoid starting-up. No start-
up, even accidental, must be allowed.
6. OPENING OF THE PUMP (continued)