2.O3 Operation
Clicking Sound is Normal
Fluid flowing through the injector will automatically cause
the injector to “click” and inject a set amount of solution
into the fluid line. The higher the flow rate the more frequent
the “clicking.” The injector is designed to inject solution
proportionally (at the same set ratio) regardless of fluid flow.
Maximum number of clicks per 15 seconds is 50.
Service Fluid Flow
Fluid flow and pressure must be within the established
specifications (see Specifications on page 5) for your model.
Change Feed (Injection) Rate
The feed rate on the injector is adjustable EVEN WHILE
OPERATING AND UNDER PRESSURE. To change feed rate
see (Fig. 1 and Fig. 2).
1. Lift lock ring (Fig. 1).
2. Rotate Ratio Adjuster Sleeve (Fig. 2) up or down to the
desired setting. Use arrows at top of the Ratio Adjuster
Sleeve to line up with the desired feed rate on the sleeve.
3. Return ring to lock position by pushing down on ring.
NOTE:
Do not screw Ratio Adjuster Sleeve below lowest
setting line. Measure outlet fluid to assure desired feed rate
is being delivered.
Bleed Port
Ensure all air is out of the unit by pressing the bleeder
button, on the lid, in until water comes out. Release bleeder
button to stop water from flowing out of bleed port.
%
Fig. 1
Fig. 2