Back Office Manual
1.00
2006
Version
March
H3
−
5
Faults
3.2
Troubleshooting
Type
Complaint
Cause
Action
Water
No water is dosed.
Pump motor defective.
Check voltage PCB
−
pump motor.
Replace defective part.
Check/replace pump motor
Float sticks in high position. Check on roughness of float and float needle.
Replace defective part.
Dosed volume
Not calibrated.
Calibrate the dispenser.
doesn’t match
Light sensor defective.
Replace the light sensor.
does
a c
programmed
volume.
Encoder disc assembled to
high.
Push the encoder disc downwards, so the
serration comes between the light sensor.
Water leakage.
Inlet valve doesn’t close
correctly.
Check/replace inlet valve.
Water tank leakage.
Fill/check the water tank.
Replace defective part.
Water is dripping or
comes from the
Dirty light sensor (water
selector).
Clean the light sensor.
co es o
e
wrong outlet.
Defective light sensor
(water selector).
Replace the light sensor.
Calcification of the water
selector outlet.
Disassemble the water selector check the
outlet.
se ec o ou e
Descale the dispenser.
Check the descaling signal (programming)
Water selector defective.
Check the function of the water selector.
Replace defective part.
Calcification between the
serration of the water
selector disc.
Disassemble the water selector check the
serration, remove calcium deposit from the
disc.
Trough dirty.
Clean Trough.
Water selector tubes badly
mounted.
Check and correct.
Tubes badly mounted upon
the Trough inlet.
Check and correct.
Condensation in
cooling
Check if the dispenser door
is properly closing
Check/replace the door locking.
cooling
compartment.
is properly closing.
Check/replace sealing.
Cooling
Bad cooling.
Peltier element badly
mounted.
Check and correct.
Dirty Peltier element.
Disassemble and clean Peltier element.
Electrical
Dispenser doesn’t
react.
Power failure.
Check wall outlet for power, power cord,
power supply.
eac
Boiling dry safety activated.
Reset/replace boiling dry safety.
Summary of Contents for Cafitesse 60
Page 1: ...Version Back Office Manual A Company 1 00 2006 700 703 054 March Part number Cafitesse 60 ...
Page 22: ...Back Office Manual 1 00 2006 Version March H3 6 Faults ...
Page 24: ...Back Office Manual 1 00 2006 Version March H4 2 Programming 4 1 1 Counters ...
Page 25: ...Back Office Manual 1 00 2006 Version March H4 3 Programming 4 1 2 Cleaning ...
Page 31: ...Back Office Manual 1 00 2006 Version March H4 9 Programming 4 2 2 Counters ...
Page 34: ...Back Office Manual 1 00 2006 Version March H4 12 Programming 4 2 6 Hot water settings ...
Page 37: ...Back Office Manual 1 00 2006 Version March H4 15 Programming 4 2 9 Clock settings Next page ...
Page 39: ...Back Office Manual 1 00 2006 Version March H4 17 Programming 4 2 10 I O tests ...