PLUMBING THE SYSTEM
3. To connect additional tanks, install a 1" barb elbow
into the bulkhead and use a 1" hose to connect the
tanks in series. Install the 3/4" plug in the
fi
nal tank.
4. At the front of the spreader, remove two of
the 3/8"
fl
ange head cap screws. Secure the
1" hose to the front plate using 1" band clamps
and mounting the hose over the holes left by the
screws. Place the removed screws back in place
with the hose clamps on them.
1" Hose
and Elbow Fittings
5. Verify that all bulkhead
fi
ttings are tightened to
20 ft-lb.
6. Install the drive cover, routing the 1/2" hose to the
manifold outside the cover and under the hose
bracket.