INDICATORS

ON = 

ILLUMINATED 

LED

OFF = 

EXTINGUISHED 

LED

ALL FLASH =

SHOW LEDS 1 THOUGH 10 ILLUMINATED ONCE PER SECOND CONTINUOUSLY

FLASH

=

ILLUMINATED ONCE PER SECOND CONTINUOUSLY

BLINK

=

ILLUMINATED ONCE ONLY 

GREEN

SHOW

LED

GREEN

PAUSE

LED

GREEN

LOOP

LED

YELLOW

START

LED

YELLOW  

END

LED

RED

RECORD

LED

STATE

OFF

OFF

OFF

OFF

OFF

OFF

UNIT NO T POW ERED

ON

OFF

OFF

OFF

OFF

OFF

PLAYBACK O F PRESET

ON

OFF

OFF

OFF

ON

OFF

PLAYBACK AT END POINT

ON

ON

OFF

OFF

OFF

OFF

PLAYBACK PAUSED

ON

ON

ON

OFF

OFF

OFF

SHOW  SET TO LOO P OR LINK

ON

ON

ON

OFF

BLINK

OFF

SHOW  AT END POINT AND
LOO PED TO START POINT

OFF

OFF

OFF

OFF

OFF

ON

RECEIVING DMX512 THE 

RERUN-A

IS LOCKED OUT FROM RUNNING
SHOW S AND IS PASSING
CONSOLE DATA TO THE OUTPUT

ALL

FLASH

OFF

OFF

OFF

OFF

ON

RECEIVING DMX512
READY TO RECORD

ON

OFF

OFF

OFF

OFF

FLASH

SHOW  CURRENTLY BEING
RECO RDED

ON

ON

OFF

ON

N/A

N/A

OFF

LOO P STATUS IN SHOW  RECORD
ON= ENABLED OFF= DISABLED

ON

FLASH

ON

N/A

N/A

N/A

OFF

ON = SELECTED SHOW
FLASH = SHOW  TO LINK TO

ON

ON

N/A

FLASH

N/A

OFF

PLAYBACK POINTER AT START OF
RECORDED SHOW

ON

ON

N/A

ON

N/A

OFF

PLAYBACK POINTER AT START
POINT

ON

ON

N/A

N/A

FLASH

OFF

PLAYBACK POINTER AT END OF
RECORDED SHOW

ON

ON

N/A

N/A

ON

OFF

PLAYBACK POINTER AT END
POINT

ALL

FLASH

FLASH

FLASH

FLASH

FLASH

FLASH

COMPACT FLASH CARD NOT
FOUND

Summary of Contents for RERUN-A

Page 1: ...RERUN ARCHITECTURAL DMX512 RECORDER MODEL RERUN A OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Software Version 1 5 Manual Revision 1 1 Serial 109001...

Page 2: ...can be supplied from a variety of sources including a 10V class 2 doorbell transformer The Rerun Architectural system can work in conjunction with a lighting console automatically switching between re...

Page 3: ...ut Circuit ESD protected EIA 485 transceiver LT1785 Output Circuit ESD protected EIA 485 transceiver LT1785 Isolation None DMX input is not isolated from DMX output Indicators Ten green SHOW LEDs One...

Page 4: ...ved nomenclature Size Faceplate 4 5 h X 4 6 w X 0 2 d Faceplate rear inset 4 15 h X 4 25 w X 0 1 d Electrical box minimum inside dimensions 2 9 h X 3 5 w X 1 5 d POWER SUPPLY The voltage provided to t...

Page 5: ...OUT C Dimmer Cabinet Common W hite Blue PW R DMX OUT Data Blue W hite PW R DMX OUT Data OPTIONAL REMOTE PANEL CABLE COLOR FROM TO USE 1 120 Ohm Data Cable Belden 9829 or Equivalent Shield XLR Plate P...

Page 6: ...oming DMX512 signals will override the Rerun Architectural levels and all shows will be locked out When removed incoming levels will be combined with those of the active show on the Rerun Architectura...

Page 7: ...OFF SHOW AT END POINT AND LOOPED TO START POINT OFF OFF OFF OFF OFF ON RECEIVING DMX512 THE RERUN A IS LOCKED OUT FROM RUNNING SHOW S AND IS PASSING CONSOLE DATA TO THE OUTPUT ALL FLASH OFF OFF OFF O...

Page 8: ...the Rerun Architectural must be connected to a DMX512 source It is recommended that your console output all 512 slots When fewer than 512 slots are received a level of 0 will be stored for all slots...

Page 9: ...d DMX512 from a console will not pass through if the Rerun Architectural is not powered Pausing a show A running show can be paused by pressing the PAUSE button When a show is paused the PAUSE LED wil...

Page 10: ...ress the REWIND button After it is pressed the START LED will turn on indicating that this point in the show is the start Note The START POINT is set to the top of the show when that show is first rec...

Page 11: ...ng selections made previously Linking This feature is for advanced users only Linking is similar to show looping However with linking when a show reaches its end instead of looping to re start itself...

Page 12: ...efault a show stops at its END POINT and the Rerun Architectural continues to send the last levels of that show until a new show is selected Each show can be set up to stop sending DMX512 data entirel...

Page 13: ...rom any show there is only one record lockout state By default the hardware lockout jumper is installed recording enabled and the software record lockout feature is disabled recording enabled The hard...

Page 14: ...hen enabled the grand master feature does not alter the levels of the incoming DMX512 levels WARRANTY Products manufactured by Doug Fleenor Design carry a five year parts and labor warranty against ma...

Reviews: