EDITING SHOW PARAMETERS 

(CONTINUED)

Grand master

A grand master feature is available as a factory option.  This feature allows the user to alter the overall
level output of the current show.  The REWIND and FORWARD buttons are used to access this feature
while the show is running.  The REWIND button raises the grand master and the FORWARD button lowers
it.

  

Note: 

!

The grand master feature can only be enabled at the factory.  It can not be enabled in the field.

!

The grand master feature is disabled by default.

!

When enabled, the grand master feature does not alter the levels of the incoming DMX512 levels.

WARRANTY

Products manufactured by Doug Fleenor Design carry a five year parts and labor warranty against
manufacturing defects.  It is the customer's responsibility to return the product to Doug Fleenor Design (at
the customer's expense).  Doug Fleenor Design will repair the unit and return it to the customer (at Doug
Fleenor Design's expense).  If a trip is necessary to the customer's site to solve a problem, the expenses
of the trip must be paid by the customer.

Note that this warranty is against Manufacturing Defects.  It does not include damage due to misuse or
abuse.  Most non-warranty repairs are made for a fixed $30.00 fee.

Summary of Contents for RERUN-A

Page 1: ...RERUN ARCHITECTURAL DMX512 RECORDER MODEL RERUN A OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Software Version 1 5 Manual Revision 1 1 Serial 109001...

Page 2: ...can be supplied from a variety of sources including a 10V class 2 doorbell transformer The Rerun Architectural system can work in conjunction with a lighting console automatically switching between re...

Page 3: ...ut Circuit ESD protected EIA 485 transceiver LT1785 Output Circuit ESD protected EIA 485 transceiver LT1785 Isolation None DMX input is not isolated from DMX output Indicators Ten green SHOW LEDs One...

Page 4: ...ved nomenclature Size Faceplate 4 5 h X 4 6 w X 0 2 d Faceplate rear inset 4 15 h X 4 25 w X 0 1 d Electrical box minimum inside dimensions 2 9 h X 3 5 w X 1 5 d POWER SUPPLY The voltage provided to t...

Page 5: ...OUT C Dimmer Cabinet Common W hite Blue PW R DMX OUT Data Blue W hite PW R DMX OUT Data OPTIONAL REMOTE PANEL CABLE COLOR FROM TO USE 1 120 Ohm Data Cable Belden 9829 or Equivalent Shield XLR Plate P...

Page 6: ...oming DMX512 signals will override the Rerun Architectural levels and all shows will be locked out When removed incoming levels will be combined with those of the active show on the Rerun Architectura...

Page 7: ...OFF SHOW AT END POINT AND LOOPED TO START POINT OFF OFF OFF OFF OFF ON RECEIVING DMX512 THE RERUN A IS LOCKED OUT FROM RUNNING SHOW S AND IS PASSING CONSOLE DATA TO THE OUTPUT ALL FLASH OFF OFF OFF O...

Page 8: ...the Rerun Architectural must be connected to a DMX512 source It is recommended that your console output all 512 slots When fewer than 512 slots are received a level of 0 will be stored for all slots...

Page 9: ...d DMX512 from a console will not pass through if the Rerun Architectural is not powered Pausing a show A running show can be paused by pressing the PAUSE button When a show is paused the PAUSE LED wil...

Page 10: ...ress the REWIND button After it is pressed the START LED will turn on indicating that this point in the show is the start Note The START POINT is set to the top of the show when that show is first rec...

Page 11: ...ng selections made previously Linking This feature is for advanced users only Linking is similar to show looping However with linking when a show reaches its end instead of looping to re start itself...

Page 12: ...efault a show stops at its END POINT and the Rerun Architectural continues to send the last levels of that show until a new show is selected Each show can be set up to stop sending DMX512 data entirel...

Page 13: ...rom any show there is only one record lockout state By default the hardware lockout jumper is installed recording enabled and the software record lockout feature is disabled recording enabled The hard...

Page 14: ...hen enabled the grand master feature does not alter the levels of the incoming DMX512 levels WARRANTY Products manufactured by Doug Fleenor Design carry a five year parts and labor warranty against ma...