Doug Fleenor Design RERUN-A Owner'S Manual Download Page 10

Page 10 of 14

EDITING SHOW PARAMETERS

 

A number of parameters can be edited in recorded shows and for system-wide functions.  These include
the start point, end point, looping/linking status, linked show number, cross fading, recording lockout, end
of show output disable, and front panel lockout.

Setting start and end points

The [REWIND] and [FORWARD] buttons are used to set the start and end points.  These buttons are only
active while a show is paused.  When paused, the buttons can be used to move the playback pointer
forward or backward through the show.  The longer each button is held, the faster the show will be
forwarded or rewound.  When the playback pointer is at the top of the recorded show, the START LED will
flash.  When the playback pointer reaches the bottom of the recorded show, the END LED will flash.  When
the playback pointer is at the START POINT, the START LED will turn on solid.  When the playback
pointer is at the end point, the END LED will turn on solid.  See below for the meanings of these terms and
for details on editing them.

Start point

The START POINT is the point in the show at which playback will begin when that show is selected.  To
set the START POINT, do the following:
1.

Start playing the show to be edited.

2.

Pause the show near the desired START POINT.

3.

While paused, use the [REWIND] or [FORWARD] buttons to move the playback pointer and locate
the desired START POINT.

4.

Press and hold the recessed [RECORD] button.  A paper clip can be used to push this button.
While holding the [RECORD] button, press the [REWIND] button.  After it is pressed, the START
LED will turn on indicating that this point in the show is the start.

Note: 

!

The START POINT is set to the top of the show when that show is first recorded.

!

The START POINT must be set to a point in the show before the END POINT.  If you attempt to set the START POINT
to a point after the END POINT , the set START POINT command will be ignored.

!

Once recorded, show data is never discarded.  If you set a START POINT a few minutes into a recorded show, those
minutes of data still exist.  You can start the show, pause it, and rewind into the previously trimmed out area.  A new
START POINT can then be set.

End point

The END POINT is the end of the show.  To set the END POINT, do the following:
1.

Start playing the show to be edited.

2.

Pause the show near the desired END POINT.

3.

While paused, use the [REWIND] or [FORWARD] button to move the playback pointer and locate
the desired END POINT.

4.

Press and hold the recessed [RECORD] button.  A paper clip can be used to push this button.
While holding the [RECORD] button, press the [FORWARD] button.  After it is pressed, the END
LED will turn on indicating that this point in the show is the END POINT.

Note: 

!

The END POINT is set to the bottom of the show when that show is first recorded.

!

The END POINT must be set to a point in the show after the START POINT.  If you attempt to set the END POINT  to
a point before the START POINT, the set END POINT command will be ignored.

!

Once recorded, show data is never discarded.  If you set an END POINT a few minutes before the bottom of a recorded
show, those minutes of data still exist.  You can start the show, pause it, and forward into the previously trimmed out
area.  A new END POINT can then be set.

Summary of Contents for RERUN-A

Page 1: ...RERUN ARCHITECTURAL DMX512 RECORDER MODEL RERUN A OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Software Version 1 5 Manual Revision 1 1 Serial 109001...

Page 2: ...can be supplied from a variety of sources including a 10V class 2 doorbell transformer The Rerun Architectural system can work in conjunction with a lighting console automatically switching between re...

Page 3: ...ut Circuit ESD protected EIA 485 transceiver LT1785 Output Circuit ESD protected EIA 485 transceiver LT1785 Isolation None DMX input is not isolated from DMX output Indicators Ten green SHOW LEDs One...

Page 4: ...ved nomenclature Size Faceplate 4 5 h X 4 6 w X 0 2 d Faceplate rear inset 4 15 h X 4 25 w X 0 1 d Electrical box minimum inside dimensions 2 9 h X 3 5 w X 1 5 d POWER SUPPLY The voltage provided to t...

Page 5: ...OUT C Dimmer Cabinet Common W hite Blue PW R DMX OUT Data Blue W hite PW R DMX OUT Data OPTIONAL REMOTE PANEL CABLE COLOR FROM TO USE 1 120 Ohm Data Cable Belden 9829 or Equivalent Shield XLR Plate P...

Page 6: ...oming DMX512 signals will override the Rerun Architectural levels and all shows will be locked out When removed incoming levels will be combined with those of the active show on the Rerun Architectura...

Page 7: ...OFF SHOW AT END POINT AND LOOPED TO START POINT OFF OFF OFF OFF OFF ON RECEIVING DMX512 THE RERUN A IS LOCKED OUT FROM RUNNING SHOW S AND IS PASSING CONSOLE DATA TO THE OUTPUT ALL FLASH OFF OFF OFF O...

Page 8: ...the Rerun Architectural must be connected to a DMX512 source It is recommended that your console output all 512 slots When fewer than 512 slots are received a level of 0 will be stored for all slots...

Page 9: ...d DMX512 from a console will not pass through if the Rerun Architectural is not powered Pausing a show A running show can be paused by pressing the PAUSE button When a show is paused the PAUSE LED wil...

Page 10: ...ress the REWIND button After it is pressed the START LED will turn on indicating that this point in the show is the start Note The START POINT is set to the top of the show when that show is first rec...

Page 11: ...ng selections made previously Linking This feature is for advanced users only Linking is similar to show looping However with linking when a show reaches its end instead of looping to re start itself...

Page 12: ...efault a show stops at its END POINT and the Rerun Architectural continues to send the last levels of that show until a new show is selected Each show can be set up to stop sending DMX512 data entirel...

Page 13: ...rom any show there is only one record lockout state By default the hardware lockout jumper is installed recording enabled and the software record lockout feature is disabled recording enabled The hard...

Page 14: ...hen enabled the grand master feature does not alter the levels of the incoming DMX512 levels WARRANTY Products manufactured by Doug Fleenor Design carry a five year parts and labor warranty against ma...