Connection
The switching point of the luminary between on and off for the PWM level is not defined: Ideally it
should be worked with a switching impulse between ground and open contact or optionally with an
impulse between ground and operating voltage. A PWM signal differing from the operating voltage
is not allowed.
Free cabling
The connect is made according to the assignment tables. The connection must be carried out ac-
cording to the required IP classification.
Attention:
In case the luminary is used without the dimming function, the PWM line (wire for the
PWM signal) must be connected to ground (-). Otherwise the LED remains off.
Connection diagram of the aquaros 5 white / monochromatic without dimmer
See respective drawing in the middle of this manual (p. 12).
Connection diagram of the aquaros 5 white / monochromatic with dimmer
See respective drawing in the middle of this manual (p. 12).
Attention:
The cable of the
aquaros 5
RGB features a wire which is not used (brown or gray). Nor-
mally, the wire is shortened ex works and should not be connected.
Connection diagram of aquaros 5 RGB
See respective drawing in the middle of this manual (p. 13).
20
en
aquaros 5 white / monochromatic
Wire color
Assignment
red
12 - 24 V DC
blue
S-PWM
black
ground (-)
aquaros 5 RGB
Wire color
Assignment
white
+ 12 V
red
red S-PWM
green
green S-PWM
blue
blue S-PWM
black
ground (-)