Mechanical installation
Installing the spot
The spot itself is fixed inside the mounting tray using the three screws. The
aquaros 5
is equipped
with a five metres long connecting cable. The connecting cable is firmly moulded in the spot. So it is
guaranteed that the connecting cable sealing in the housing is waterproof.
When installing stainless steel screws and nuts, only stainless steel tools must be used.
At first, run the cable through the installation sleeve, the cable gland and the empty conduit. Leave
enough cable inside the mounting tray to be able to lift the spot above the water surface while it is
still connected (approx. 1 m cable length). Tighten only the cable gland in order to seal the cable
outlet.
The mounting tray also seals without the spot, however, the cable outlet must be sealed. In case
the mounting tray is placed under water without installing the spot, the cable gland must be sealed
using a substitute for the cable.
Now, insert the spot, spirally roll up the excess connecting cable inside the installation sleeve. Press
the spot flat against the pool wall or the sealing flange of the mounting tray (according to the pool
quality and the installation set) and loosely tighten it using the three screws. The spot DOES NOT
seal against the pool wall / installation sleeve, the mounting tray is flooded later. Therefore, it is
sufficient to apply a tightening torque to the screws that holds the spot physically.
Tightening torque of the M3 fixing screws: max. 2 Nm.
Now, connect the spots.
Installation of other accessories
During the installation of other accessories, refer to the respective installation instructions at-
tached.
Connection
Attention:
The design of the complete system and of the required power supplies must be carried
according to the protective low voltage SELV prescriptions!
The
aquaros 5
is supplied with DC power and dimmed via a separate PWM signal (pulse width
modulation). A PWM signal (S-PWM) is required for each light color. The PWM input has the following
characteristics:
19
en
PWM line connected to ground (-)
LED on
PWM line open
LED off
PWM line connected to operating voltage (+)
LED off
PWM frequency = 0 to 1,000 Hz