AssuredSAN 4004 Series FRU Installation and Replacement Guide
31
3.
Select the
Restart
operation.
4.
Select the controller type to restart: Management or
Storage
.
5.
Select the controller module to shut down: A, B, or both.
6.
Click
OK
. A confirmation panel appears.
7.
Click
Yes
to continue; otherwise, click
No
. If you clicked Yes, a message describes shutdown activity.
NOTE:
If an iSCSI port is connected to a Microsoft Windows host, the following event is recorded
in the Windows event log:
Initiator failed to connect to the target
.
To restart the controller using RAIDar (v2):
1.
Sign-in to RAIDar using default user
manage
and password
!manage
.
If the default user or password—or both—have been changed for security reasons, enter the secure
login credentials instead of the system defaults shown above.
2.
In the Configuration View panel, right-click the system and select
Tools
>
Shut Down
or
Restart
Controller
.
3.
In the main panel, set the options:
•
Operation
: Select
Restart
.
•
Controller Type
: Select the controller type to restart:
Management
or
Storage
.
•
Controller
: Select the controller module to restart:
A
,
B
, or
Both
.
4.
Click
Restart now
. A confirmation panel appears.
5.
Click
Yes
to continue; otherwise, click
No
. If you click Yes, a second confirmation diagram appears.
6.
Click
Yes
to continue; otherwise, click
No
. If you click Yes, a message describes restart activity.
NOTE:
If an iSCSI port is connected to a Microsoft Windows host, the following event is recorded
in the Windows event log:
A connection to the target was lost, but Initiator
successfully reconnected to the target
.
Using the CLI
You can set a CLI preference to use v3 or v2 terminology in command output and system messages.
See TIP bullets regarding CLI “default management mode” and “current management mode”
.
If the enclosure’s Unit Locator LED is on, run the following command to turn it off:
set led enclosure 0 off
If the Fault/Service Required LED is amber, the controller module has not gone online, and likely failed its
self-test. Put the module online by restarting the controller, or by checking the event log for errors.
To restart the Management Controller (A or B), run the following command:
restart mc
a
or
restart mc
b
or
restart mc
both
To restart the Storage Controller (A or B), run the following command:
restart sc
a
or
restart sc
b
or
r
estart sc
both
TIP:
See the
AssuredSAN 4004 Series Setup Guide
for descriptions of model-specific LEDs.
Updating firmware
You can view the current versions of firmware in controller modules, expansion modules (in drive
enclosures), and disks, and you can also install new firmware versions.