Dostmann 5020-1362 Instruction Manual Download Page 8

 

IX.   BATTERY REPALCEMENT 

1. As battery power is not sufficient, 

 will be shown on LCD. 

Replace with 6 pcs new of 1.5V size AAA batteries is required. 

2.  After  the  temperature  probe  is  disconnected  and  the  meter  is 

powered off, remove the battery cover. 

3.  Remove  batteries  from  the  holder  and  replace  it  with  6  pcs  of 

new 1.5V size AAA alkaline batteries. 

4. Secure the battery cover. 

 
 

Summary of Contents for 5020-1362

Page 1: ...ltages above 60VDC or 24VAC RMS Such voltages pose a shock hazard Environment conditions Altitude up to 2000 meters Indoor use only Relatively humidity 95 max Operation Temperature 0 50 32 122 Maintenance Clearing Repairs or servicing not covered in this manual should only be performed by qualified personnel Periodically wipe the case with a dry cloth Do not use abrasives or solvents on this instr...

Page 2: ...ght Approx 430g with batteries thermo paper Accessories Carrying case Instruction manual Batteries 2 Rolls of thermo paper type K probe Printer Thermo printing type with 16 characters per line using 38mm width plain thermo paper 2 2 2 Electrical Specifications Humidity Range 10 RH to 95 RH Resolution 0 1 RH Accuracy 3 RH from 30 RH to 95 RH 5 RH from 10 RH to 30 RH Temperature T1 Range 20 to 60 4 ...

Page 3: ... FEED PAPER Fig 2 Key for moving forward thermo paper one line Perform force stop printing and skip any printing data 7 DEW POINT Key for changing humidity to dew point display 8 MAX MIN Fig 2 Press this key one time to enter maximum minimum record mode the REC symbol is displayed Press this key to display the maximum reading MAX REC symbol displayed the minimum reading MIN REC symbol displayed an...

Page 4: ... indicator 9 T1 measurement indicator 10 T1 measured value NTC 11 T2 measurement indicator 12 T2 measured value Type K 13 Temperature measurement units 14 Humidity measurement unit 15 Recording indicator 16 Minimum measurement value indicator 17 Maximum measurement value indicator 18 Data hold indicator 19 Humidity and dew point temperature measured value IV PRECAUTIONS AND PREPARATIONS FOR MEASUR...

Page 5: ...ode the printer will print data as follows INTV 00 06 10 55 19 08 16 62 7 RH td 19 8 T1 27 6 T2 26 5 10 55 25 08 16 62 7 RH td 19 8 T1 27 6 T2 26 5 8 10 55 31 08 16 62 7 RH td 19 8 T1 27 6 T2 26 5 10 55 37 08 16 62 7 RH td 19 8 T1 27 6 T2 26 5 Press PRINT or FEED key to exit printing mode When the meter is powered on if the printing function setting is ON and now time is interval printing start ti...

Page 6: ...er setting press or button to increase or decrease the parameter Parameter setting in sequence and LCD display as follows 1 Printing function ON or OFF select fig 4 2 Interval printing second parameter setting fig 5 3 Interval printing minute parameter setting fig 6 10 4 Printing start time minute parameter setting fig 7 5 Printing start time hour parameter setting fig 8 6 Printing stop time minut...

Page 7: ...ime setting mode set minute hour from 00 00 to 23 59 4 Select stop printing time setting mode set minute hour from 00 00 to 23 59 5 When finish the setting press MENU key to exit the setting mode LCD will display mark at left upper corner Note The start time must be earlier than the stop time otherwise the buzzer will beep to warning the setting is error and not accept this setting when press MENU...

Page 8: ...lace with 6 pcs new of 1 5V size AAA batteries is required 2 After the temperature probe is disconnected and the meter is powered off remove the battery cover 3 Remove batteries from the holder and replace it with 6 pcs of new 1 5V size AAA alkaline batteries 4 Secure the battery cover ...

Reviews: