1.NOTE:
Water going through injector must be free of sand, dirt and grit. Installation of 140 mesh
(104 micron) or finer filter will be required.
2. MOUNT INJECTOR:
Securely to a solid object such as a wall. Note arrow on injector indicat-
ing water flow.
See fig. 3.
3. BACKFLOW PREVENTOR:
Install one adequately sized that meets your local code require-
ments.
4. BYPASS VALVE:
To bypass injector when not in service or to service injector pipe in the three
valve bypass arrangement as shown in Fig. 4
5. CHECK SYSTEM FOR LEAKS:
Open the bypass valve (A), close valves (B) and (C) so that
the water wil not flow into injector
SLOWLY
turn on the main water line so that water will
run through the plumbing system. Turn on all of the valves located downstream from your injector
to release trapped air. Slowly turn on the inlet valve (B). Open the outlet valve (C) at injector outlet.
Close (A). As water travels freely through your injector, you willhear a soft “clicking” sound.
6. SOLUTION CONTAINER:
Refer to figure 4. You may use any size container but we recom
-
mend using one with a lid or cover. To connect your solution container gently push the end of the
suction tube (#25) onto the bottom of the fitting assembly (#11). Place the filter into the solution
container at least 2 inches (5cm) from the bottom. Cover the solution filter with at least 2 inches.
(5cm) of chemical solution.
INSTALLATION:
5