5

Grab the other end of the 

ORPDT 

on the inlet side 

of the

 PRV, 

and attach it to the Discharge Valve of 

the pump’s head. Follow instructions in step 16 to 

attach the tube. 

Mount the

 PRV 

to the wall or surface using 1/4” 

screws/bolts. Make sure the tube runs with no 

tension from the pump to the 

PRV.

 

 

Grab the Injection Valve from the pump box. Cut 

the tip of the valve to the threads level, see image. 

Insert the Injection Valve into the

 Reducer 

Bushing 

at the top of the 

Tee 

in the

 Micro-Doser 

Plumbing Assembly, 

hand tighten only. 

Anchor the 

Micro-Doser Plumbing Assembly 

to 

the wall or surface, right underneath the pump. 

 

Remove the Nut, Collar, and Nozzle from the top 

of the Injection Valve, and attach the tube from 

the outlet side of the 

PRV,

 following the same 

procedure in step 16.

Your 

Micro-Doser Kit 

assembly is now connected 

to your pump. 

18

19

20

21

22

Discharge 

Valve

PRV 

inlet

PRV 

outlet

23

cut here 

for 3/4” 

lines

flow

flow

Summary of Contents for Dilution Solutions MDE0110MF.75KIT

Page 1: ...3 4 Micro Doser Kit Manual NOTE Installation illustrations are to be used as a reference guide only Part MDE0110MF 75KIT...

Page 2: ...age Threaded Union BK034 U 2 Check Valve CV34 PH 1 Tee TT34 1 to Reducer Bushing RB75 50ET 1 Close Nipple NIP075 2 3 Thread Tape TEF12 1 Included in the MicroDoser Kit Micro Doser Kit Contents PACK Pa...

Page 3: ...art Part Number Qty Part Image Digital Manual Support Videos QR Tag TAG MD 1 1 PACK Part Part Number Qty Part Image eOne MF 0110 PEU483891MEA 1 tubing kit One pump PACK Part Part Number Qty Part Image...

Page 4: ...image Hand tighten the Nut Wrap Thread Tape 4 to 5 times on all threads Make sure to wrap tape clockwise to prevent from unraveling Attach a Union to the inlet side of the Water Meter Make sure the ar...

Page 5: ...e the arrow on the Mixing Chamber points in the direction of the flow Insert the third Close Nipple in the outlet of the Mixing Chamber and attach the last Union to the other side of the Close Nipple...

Page 6: ...o not overtighten Take your pump from its box and mount it on the wall using the bracket included with the pump Grab the Opaque Rigid Polyethylene Discharge Tube ORPDT included with the pump and cut i...

Page 7: ...e to the threads level see image Insert the Injection Valve into the Reducer Bushing at the top of the Tee in the Micro Doser Plumbing Assembly hand tighten only Anchor the Micro Doser Plumbing Assemb...

Page 8: ...chemical container Next connect the pump to the Water Meter see steps 28 33 below CONNECTING THE WATER METER You will need a punch and a small flat head screwdriver To connect the pump to the Water Me...

Page 9: ...air bleed nut Push the START STOP button to begin the priming functions The pump will begin to stroke click Once the chemical starts going down the air bleed tube re tighten the air bleed nut back up...

Page 10: ...TART STOP button to begin the program operation You can now turn on the irrigation water to begin operation of the system using the water meter 7 8 9 10 See operating manual for complete instructions...

Page 11: ...ed injection will be minimal but fluctuations may be noticeable at very low or very high flow rates See USING THE PRESSURE RELIEF VALVE to decrease the Single Pulse Volume to a volume that divides eve...

Page 12: ...IC TESTING PROCEDURE steps Repeat steps 3 4 as necessary until desired Single Pulse Volume is reached 1 2 3 4 5 Black Protection Cap Counter Nut Adjustment Screw Volumetric Testing Procedure You can t...

Page 13: ...e Settings Press button the screen should read PULSES MINUTE PULSES NUM 300 Press buttons to set PULSES MINUTE to 100 100 pulses min Press the button to save the new PULSE MINUTE settings Open Test Du...

Page 14: ...iner from the graduated cylinder and place the suction strainer back in the concentrate container Return concentrate solution remaining in graduated cylinder to concentrate container to eliminate wast...

Page 15: ...Chamber Sunshade sleeve prevents the light from impacting nutrient rich water eliminating the potential for biofilm and algae growth in the chamber Now attach the QR Code tag included to the MicroDos...

Page 16: ...Dilution Solutions 2090 Sunnydale Blvd Clearwater FL USA 1 800 451 6628 727 451 1198 www dilutionsolutions com...

Reviews: