Dornbracht
Sensory Sky
ATT
Planning
guide
Page 13/38
DN 20 WW
DN 15
Z
DN 20 KW
min. 900
The following components (scope of delivery) have to be positioned to be accessible at all times:
– 4 x Shut off for hot and cold water pipes (DN 20)
– 2 x Filter for hot and cold water pipes (DN 20)
– 2 x Backflow preventer Type BA according to eN 1717 for hot and cold water pipes
- With a circulation pipe, the minimum distance to the eVALVe of the hand shower set must be 900 mm.
- The nominal diameter (DN 20) has to be adhered to for both pipes and fittings.
see Planning information
DN 20
DN 20
Water installation
Positioning
recommendations
Components
Zones of protection
Pre-wall installation
Data and standards
Product overview
Checklists
Concealed rough parts rain panel +
Hand shower set
Water installation - schema
electrical installation
electrical installation - schema
Installation pre-wall
Concealed rough parts for
electronic control elements
Cutouts / anchoring points