![Dorna 110DNA-04C User Manual Download Page 27](http://html.mh-extra.com/html/dorna/110dna-04c/110dna-04c_user-manual_2523065027.webp)
27
Chapter 6 Parameters
6.1 Parameters
6.1.1 Basic parameters
paramet
er code
parameter Name & functions
Set range
unit
Default
value
Effective
PA000
password
0~9000
58
PA001
Carrier frequency
5~10
KHz
8
re-power
on
PA003
Initial display status
To select display status when power on.
0~40
0
re-power
on
PA004
Control mode selection
Refer to 3.1
0~7
0
re-power
on
PA110
Function selection parameter
Refer to 3.1
0~10
0
PA009
Motor model select
0
~
280
——
re-power
on
6.1.2 Function selection parameter
param
eter
code
parameter Name & functions
Set range
unit
Default
value
Effective
PA006
Function selection parameter
0~65535
0
re-power
on
Place
Definition
Status setting
0
1
bit0
CWL & CCWL control signal
signal
valid
signal
invalid
bit1
Input direction signal (SIGN) negation
invalid
operation
valid
operation
bit2
Input pulse signal (PULSE) negation
invalid
operation
valid
operation
bit3
Save 2 parameters to EEPROM when
power off
invalid
operation
valid
operation
bit4
Save motor turns when power off
invalid
operation
valid
operation
bit5
Speed display DP[0] negation
invalid
operation
valid
operation
bit6
ZEROSPD control signal
signal
valid
signal
invalid