dormakaba TS9356 PKT 120/170 (Closer on door)
Installation Instructions
08279971
08-2019
TS93 Surface Applied Closers
3
Technical specifications
1 Technical specifications
1.1 Overview
Caution: sex nuts are required for attachment of
components to unreinforced doors and to wood
or plastic faced composite type fire doors, unless
an alternative method is identified in the
individual door manufacturer’s listings.
Maximum degree of opening is 170°.
Minimum door width is 32”.
Adjust closer spring tension for proper closing
and latching of door.
Adequate reinforcement by others required to
install track in pocket.
Pocket depth is measured from the pull side face
of the door at maximum opening.
Closer
Door width range Maximum
weight
TS9356 PKT 120/170
2’-8” to 4’”
150lbs
Requires DORMA EM504 electromagnetic door
holder
Use closer body style “B” for this installation.
Arrows on closer mounting plate point upward.
Follow included template to properly prepare
door and frame for all accessories of the closer
installation.
Know the swing of the door which is being
installed prior to installation.
Make sure door efficiently operates prior to
installing closer.
Verify closer spring size prior to installation.
Table 1
Table 2
Drill bits:
#2 Phillips screwdriver
Metal: No. 21 & 10-32 tap
M2.5 hex key
Wood: 1/8”
M5 hex key
1.2 Size selection chart
1.3 Tools recommended