background image

TS9356 PKT 120/170

Surface Applied Closer
Pocket door track mount in 120°/170° pocket
(Closer on wall)

Installation instructions

08279971 – 08-2019

EN

 | 

Summary of Contents for TS9356 PKT 120/170

Page 1: ...TS9356 PKT 120 170 Surface Applied Closer Pocket door track mount in 120 170 pocket Closer on wall Installation instructions 08279971 08 2019 EN ...

Page 2: ... Size selection chart 3 1 3 Tools recommended 3 1 4 Surface closer system 4 1 5 Handing the door 4 2 Installation instructions 5 2 1 Installing the back plate 5 2 2 Installing the surface closer 5 2 3 Installing track assembly 5 2 4 Installing main arm 6 2 5 Secure main arm 6 3 Adjustments 7 3 1 Adjust closing speeds sweep latch backcheck delayed action 7 3 2 Adjust spring force 8 4 Install covers...

Page 3: ...equired to install track in pocket Pocket depth is measured from the pull side face of the door at maximum opening Closer Door width range Maximum weight TS9356 PKT 120 170 2 8 to 4 150lbs Requires DORMA EM504 electromagnetic door holder Use closer body style B for this installation Arrows on closer mounting plate point upward Follow included template to properly prepare door and frame for all acc...

Page 4: ...eft hand door LH Left hand reverse door LHR Right hand reverse door RHR Right hand door RH 1 4 Surface closer system Fig 2 The surface closer is comprised of the following components 1 Closer body 2 Main arm 3 Track assembly 4 Pinion 5 Cover and end caps 6 Closing sweep speed adjustment 7 Latch speed adjustment 8 Backcheck adjustment 9 Delayed action adjustment 10 Backplate 1 5 Handing the door 1 ...

Page 5: ... surface closer NOTE Orient pinion 1 closest to hinge 2 2 1 Secure the closer body 2 to the plate using the four M5x47mm flathead Phillips screws 3 provided with the plate itself 2 2 Installing the surface closer 2 3 Installing track assembly Fig 4 Fig 5 Fig 3 2 3 1 Position the components inside the track channel 1 2 3 2 Attach the track channel to the wall through the end blocks with two flat he...

Page 6: ...5mm shoulder bolt 2 using an M5 hex key 2 5 1 With the door closed and using an adjustable wrench looking up at the bottom of the closer Left hand door turn the bottom pinion clockwise approximately 5 Right hand door turn the bottom pinion counter clockwise approximately 5 2 5 2 Attach the main arm 1 to the top pinion with an M6x20 socket head cap screw 2 using an M5 hex key Be sure that the door ...

Page 7: ... Increase sweep speed Turn valve counter clockwise Decrease sweep speed Turn valve clockwise 3 1 2 Adjust the closing latch speed 2 for the area from 7 0 Increase latch speed Turn valve counter clockwise Decrease latch speed Turn valve clockwise 3 1 3 Adjust the opening backcheck 3 Increase resistance Turn valve clockwise Decrease resistance Turn valve counter clockwise 3 1 4 Adjust the closing de...

Page 8: ... Install covers Fig 10 4 1 1 Snap both end covers 1 into place 4 1 2 Remove the un needed tab 2 and snap the closer body cover 3 into place 4 1 3 Secure with a 4 40 Phillips pan head screw 4 Increase Decrease TS9356 NOTE Supplied with a size 6 spring setting Increase force turn clockwise 6 times max Door width Full turns of spring adjust Closer size TS9356 4 0 5 4 6 5 6 2 1 4 3 1 3 ...

Page 9: ...www dormakaba com dormakaba DORMA USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...